12.2.8 UA-OFF monitoring board

The UA-OFF monitoring board is an alternative to the short bridge card in the
pneumatic supply plate. See g Fig. 19.
The electrical UA-OFF monitoring board monitors the actuator voltage UA for
state UA < UA-OFF. All voltages are passed through directly. The UA-OFF monitor-
ing board must therefore always be installed after an electrical supply plate to be
monitored.
In contrast to the bridge card, the UA-OFF monitoring board has to be taken into
account when configuring the control.

12.2.9 Possible combinations of base plates and cards

4x valve driver boards are always combined with two 2x base plates.
The table below shows the possible combinations of base plates, pneumatic sup-
ply plates, electrical supply plates, and transition plates with various valve driver
boards, bridge cards, and supply boards. See g Table 26.
Table 26: Possible combinations of plates and cards
Base plate
Base plate, 2x
Base plate, 3x
Two base plates, 2x
Pneumatic supply plate
Transition plate and pneumatic supply plate
Electrical supply plate
1) nn = module no. 00 to 2A (hexadecimal), corresponds to 00 to 42 (decimal)
The boards in the AV-EP base plates are installed permanently and can
therefore not be combined with other base plates.

12.3 Identifying the Modules

12.3.1 Material number for bus coupler

12
AES-D-BC-XXXX
R4120XXXXX
The bus coupler can be clearly identified using its material number. When ex-
changing the bus coupler, you can use the material number to reorder the same
unit.
The material number is printed on the name plate (12) on the back of the device
and on the top below the identification key. The material number for the AES se-
ries bus coupler for Ethernet POWERLINK is R412018226.

12.3.2 Material number for valve system

The material number for the complete valve system (46) is printed on the right
end plate. You can use this material number to reorder an identically configured
valve system.
Note that, after a valve system conversion, the material number still refers to
u
the original configuration (see
AVENTICS™ Ethernet POWERLINK | R412018143-BAL-001-AH | English
Board
Valve driver board, 2x
Valve driver board, 3x
1)
Valve driver board, 4x
Short bridge card or
UA-OFF monitoring board
Long bridge card
Supply board
7291
46
g 12.5.5 Conversion
documentation).

12.3.3 Identification key for bus coupler

The identification key (1) on the top of the AES series bus coupler for Ethernet
POWERLINK is "AES-D-BC-EIP" and describes the unit's main characteristics:
Table 27: Meaning of the identification key
Designation
Meaning
AES
Module from the AES series
D
D design
BC
Bus Coupler
PWL
For Ethernet POWERLINK fieldbus protocol

12.3.4 Equipment identification for bus coupler

The bus coupler requires a unique ID to enable the clear identification of the unit
within the system. The two equipment identification fields (4) on the top and
front of the bus coupler are available for this purpose.
Label the two fields as shown in your system diagram.
u

12.3.5 Bus coupler name plate

The name plate is located on the back of the bus coupler. It contains the follow-
ing information:
47
48
AES-D-BC-XXXX
49
R4120XXXXX
50
51
52
53
54
55
Fig. 20: Bus coupler name plate
47
Logo
49
Material number
51
Power supply
53
Serial number
56
Data Matrix code
58
Internal plant ID
1
4
58
57
7291
56
48
Series
50
MAC address
52
Manufacture date (FD) with format
"FD: <YY>W<WW>"
55
Country of manufacture
57
CE mark
49