7 Structure of the Electrical Supply Plate Data

The electrical supply plate interrupts the UA voltage coming from the left and
transfers the voltage supplied by the additional M12 plug to the right. All other
signals are directly passed on.

7.1 Process data

The electrical supply plate does not have any process data.

7.2 Diagnostic data

The electrical supply plate sends a manufacturer-specific diagnostic message to
the bus coupler, which indicates a missing actuator voltage (UA) or that the sys-
tem has fallen below the tolerance value of 21.6 V DC (24 V DC -10% = UA-ON).
The diagnosis is structured as follows:
In the User Structure Identifier (USI) (first 16-bit value), the slot number is coded
and 0x0040 is sent in the diagnostic data (second 16-bit value). This corresponds
to a group diagnosis.
If several diagnoses are available, for example if a short circuit is detected in sev-
eral modules, each diagnosis is set and also reset individually.

7.3 Parameter data

The electrical supply plate does not have any parameters.
8 Structure of Pneumatic Supply Plate Data with
UA‑OFF Monitoring Board
The electrical UA-OFF monitoring board transfers all signals including the supply
voltages. The UA-OFF monitoring board recognizes whether the UA voltage falls
below the UA-OFF value.
8.1 Process data
The electrical UA-OFF monitoring board does not have process data.
8.2 Diagnostic data
The UA-OFF monitoring board sends a manufacturer-specific diagnostic message
to the bus coupler, which signalizes that the actuator voltage (UA) has fallen be-
low the minimum (UA < UA-OFF).
The diagnosis is structured as follows:
In the User Structure Identifier (USI) (first 16-bit value), the slot number is coded
and 0x0040 is sent in the diagnostic data (second 16-bit value). This corresponds
to a group diagnosis.
If several diagnoses are available, for example if a short circuit is detected in sev-
eral modules, each diagnosis is set and also reset individually.
8.3 Parameter data
The electrical UA-OFF monitoring board does not have parameters.

9 Presettings on the Bus Coupler

Configuration error!
An incorrect valve system configuration can cause malfunctions in and dam-
age to the overall system.
1. The configuration may only be carried out by qualified personnel (see "Per-
sonnel qualifications").
2. Observe the specifications of the system owner as well as any restrictions
resulting from the overall system.
3. Observe the documentation of your PLC configuration program.
The following pre-settings must be made using the PLC configuration program:
• Assigning a clear name to the bus coupler (see "Assigning names, IP ad-
dresses, and subnet masks")
• Setting diagnostic messages (see "Setting the bus coupler parameters")
AVENTICS™ AES PROFINET IO | R412018140-BAL-001-AH | English
NOTICE
• Setting the module parameters via the controller (see "Setting parameters for
the modules")

9.1 Opening and closing the window

Defective or improperly positioned seal!
Water may enter the device. The protection class IP65 is no longer guaranteed.
1. Make sure that the seal below the window (3) is intact and properly posi-
tioned.
2. Make sure that the screw (25) has been securely tightened with the correct
torque (0.2 Nm).
1. Loosen the screw (25) on the window (3).
2. Lift up the window.
3. Carry out the settings as described in the next steps.
4. Close the window. Ensure that the seal is positioned correctly.
5. Tighten the screw.
Tightening torque: 0.2 Nm

9.2 Changing the name

An address change will not be effective during operation!
The bus coupler will continue to work with the previous address.
1. Never change the address during operation.
2. Disconnect the bus coupler from the power supply UL before changing the
positions of switches S1 and S2.

9.3 Assigning names, IP addresses, and subnet masks

The bus coupler in the PROFINET IO network needs a clear name in order to be
recognized by the controller.
The name can be assigned in two ways:
• Manually or
• With PROFINET IO functions
Name on delivery
On delivery, switches S1 and S2 are set to 0. As a result, name assignment with
PROFINET IO functions is activated.
3
25
NOTICE
NOTICE
34

Quicklinks ausblenden:

Werbung

Inhaltsverzeichnis
loading

Inhaltsverzeichnis