1 About this documentation

1.1 Documentation validity

This documentation is valid for the AES series bus couplers for Ethernet POWER-
LINK with material numbers R412018226 (Gen.1) and R412088226 (Gen.2). This
documentation is geared toward programmers, electrical engineers, service per-
sonnel, and system owners.
This documentation contains important information on the safe and proper com-
missioning and operation of the product and how to remedy simple malfunctions
yourself. In addition to a description of the bus coupler, it also contains informa-
tion on the PLC configuration of the bus coupler, valve drivers, and I/O modules.

1.2 Required and supplementary documentation

Only commission the product once you have obtained the following docu-
u
mentation and understood and complied with its contents.
Table 1: Required and supplementary documentation
Documentation
System documentation
Documentation of the PLC configuration pro-
gram
Assembly instructions for all current compo-
nents and the entire AV valve system
System descriptions for connecting the I/O
modules and bus couplers electrically
Operating instructions for AV-EP pressure
regulators
All assembly instructions and system descriptions for the AES and AV
series, as well as the PLC configuration files, can be found on the CD
R412018133.

1.3 Presentation of information

1.3.1 Warnings
In this documentation, there are warning notes before the steps whenever there
is a risk of personal injury or damage to equipment. The measures described to
avoid these hazards must be followed.

Structure of warnings

Hazard type and source
Consequences of non-observance
Precautions
u
Meaning of the signal words
Immediate danger to the life and health of persons.
Failure to observe these notices will result in serious health consequences, in-
cluding death.
Possible danger to the life and health of persons.
Failure to observe these notices can result in serious health consequences, in-
cluding death.
Possible dangerous situation.
Failure to observe these notices may result in minor injuries or damage to
property.
Possibility of damage to property or malfunction.
Failure to observe these notices may result in damage to property or malfunc-
tions, but not in personal injury.
AVENTICS™ Ethernet POWERLINK | R412018143-BAL-001-AH | English
Document type
Comment
Operating instruc-
To be created by sys-
tions
tem owner
Software manual
Included with soft-
ware
Assembly instructions Printed documenta-
tion
System description
PDF file on CD
Operating instruc-
PDF file on CD
tions
SIGNAL WORD
DANGER
WARNING
CAUTION
NOTICE

1.3.2 Symbols

Recommendation for the optimum use of our products.
Observe this information to ensure the smoothest possible operation.

1.4 Designations

The following designations are used in this documentation:
Table 2: Designations
Designation
Meaning
Backplane
Internal electrical connection from the bus coupler to the valve driv-
ers and the I/O modules
Left side
I/O zone, located to the left of the bus coupler when facing its elec-
trical connectors
Module
Valve driver or I/O module
Right side
Valve zone, located to the right of the bus coupler when facing its
electrical connectors
POWERLINK
Ethernet-based fieldbus system
Stand-alone system
Bus coupler and I/O modules without valve zone
Valve driver
Electrical valve actuation component that converts the signal from
the backplane into current for the solenoid coil

1.5 Abbreviations

This documentation uses the following abbreviations:
Table 3: Abbreviations
Abbreviation
Meaning
AES
Advanced Electronic System
AV
Advanced Valve
B&R controller
Control from Bernecker + Rainer Industrie-Elektronik Ges.m.b.H.
CPF
Communication Profile Family
I/O module
Input/Output module
FE
Ground (Functional Earth)
MAC address
Media Access Control address (bus coupler address)
nc
not connected
PDO
Process Data Object
SDO
Service Data Object
PLC
Programmable Logic Controller or PC assuming control functions
UA
Actuator voltage (power supply for valves and outputs)
UA-ON
Voltage at which the AV valves can always be switched on
UA-OFF
Voltage at which the AV valves are always switched off
UL
Logic voltage (power supply for electronic components and sensors)
XDD
XML Device Description

2 Notes on safety

2.1 About this chapter

The product has been manufactured according to the accepted rules of current
technology. Even so, there is danger of injury and damage to equipment if the
following chapter and safety instructions of this documentation are not followed.
1. Read these instructions completely before working with the product.
2. Keep this documentation in a location where it is accessible to all users at all
times.
3. Always include the documentation when you pass the product on to third par-
ties.

2.2 Intended use

The AES series bus coupler and AV series valve drivers are electronic components
developed for use in the area of industrial automation technology.
The bus coupler connects I/O modules and valves to the Ethernet POWERLINK
fieldbus system. The bus coupler may only be connected to valve drivers from
AVENTICS and I/O modules from the AES series. The valve system may also be
used without pneumatic components as a stand-alone system.
The bus coupler may only be actuated via a programmable logic controller (PLC),
a numerical controller, an industrial PC, or comparable controllers in conjunction
with a bus master interface with the Ethernet POWERLINK V2 fieldbus protocol.
31