nents (see
g 12.5.3 Impermissible
modules can be connected on the left side. The unit can also be operated without
pneumatic components, i.e. with only a bus coupler and I/O modules, as a stand-
alone system.
The figure below shows an example configuration with valves and I/O modules.
See g Fig. 11. Depending on the configuration, your valve system may contain
additional components, such as pneumatic supply plates, electrical supply plates,
or pressure regulators (see
g 12.2 Valve
29
28
27
26
Fig. 11: Example configuration: unit consisting of AES series bus coupler and I/O
modules, and AV series valves
26
Left end plate
28
Bus coupler
30

Pneumatic supply plate

32
Right end plate
34
Electrical unit, AES series

12.2 Valve Zone

The figures below show the components as illustrations and symbols.
The symbol representations are used in
Valve
Zone.

12.2.1 Base plates

The valves from the AV series are always mounted on base plates that are assem-
bled into blocks so that the supply pressure is applied to all valves.
The base plates are always 2x or 3x base plates for two or three single or double
solenoid valves.
Fig. 12: Base plates, 2x and 3x
(1)
Valve position 1
(3)
Valve position 3
21
21 Base plate, 3x
AVENTICS™ Ethernet POWERLINK | R412018143-BAL-001-AH | English
configurations). Up to 10 input and output
Zone).
31
30
33
34
27
I/O modules
29

Transition plate

31
Valve driver (concealed)
33
Pneumatic unit, AV series
g 12.5 Conversion of the
20
21
(2)
Valve position 2
20
20 Base plate, 2x
12.2.2 Transition plate
The transition plate (29) has the sole function of mechanically connecting the bus
coupler to the valve zone. It is always located between the bus coupler and the
first pneumatic supply plate.
32
Fig. 13: Transition plate
12.2.3 Pneumatic supply plate
Pneumatic supply plates (30) can be used to divide the valve system into sections
with different pressure zones (see
Fig. 14: Pneumatic supply plate

12.2.4 Electrical supply plate

The electrical supply plate (35) is connected to a supply board. It can feed in an
extra 24 V power supply for all valves located to the right of the electrical supply
plate via an integrated 4-pin M12 connection. The electrical supply plate moni-
tors the additional power supply (UA) for low voltage.
20
Fig. 15: Electrical supply plate
The tightening torque of the M4x0.7 ground screw (WS 7) is 1.25 Nm +0.25.
Pin assignments of the M12 plug
The connection for the actuator voltage is an M12 plug, male, 4-pin, A-coded.
Please see the table below for the pin assignments of the M12 plug on the
u
electrical supply plate. See g Table 25.
21
Fig. 16: Pin assignment M12 plug
29
29
g 12.5 Conversion of the Valve
30
30
P
24 DC - 10%
35
35
UA
2
1
3
4
X1S
Zone).
47