12.2.1

Deactivating of Dongle Box respective OGM

The following procedure is applied to re-disable a peripheral unit
which had previously been connected and has then been removed again, in the pump
software.
Cancel the alarm signal which appears by pressing the Start/Stop button.
The following appears in the display unit:
Fig. 12.14
Operating faults: Deactivating of DongleBox in the pump software 1
Deactivation can be selected by pressing the  or button and following is displayed
Fig. 12.16
Operating faults: Deactivating of DongleBox in the pump software 2
The setting is taken over through pressing the Start/Stop button
12.3

Trouble shooting

Fault
metering pump does not work, no
display indicator
pump has no suction despite venting
and max. strokes
low-level indicator
the display despite a full container
Prior to repair and maintenance work and metering of dangerous media, always rinse the
CAUTION
metering head, relieve the pressure pipe and wear protective clothing (protective goggles,
gloves and apron).
Electronics repairs must only be performed by trained electricians, following the safety
regulations of the professional association VB G 4 and ZH 1/11)!
When opening the covers or removing parts, except when this is possible without tools,
CAUTION
voltage-carrying parts may be exposed. Connection points may also be under live
voltages.
Before calibration, maintenance, repairs or replacement of parts, the device must be
disconnected from all voltage sources if it is necessary to open up the device.
417101799_EMP_IV_E60.docx
Dongle-Box
Dongle-Box
Possible cause
mains power cable damaged
incorrect voltage
wrong connection
deposits, adhesions or drying-out of
the valves
float of the suction pipe is jammed
suction pipe plug or strapping plug is
appears on
loose or not plugged in
suction pipe cable is faulty
PLUS
in the pump software
Fig. 12.15
Operating faults: Deactivating of OGM
Fig. 12.17
Operating faults: Deactivating of OGM
Remedy
change mains power cable
check mains voltage
check connections acc. clamp plan
rinse the metering head through the
suction line, if necessary remove and
clean or replace the valves
unjam the float
tighten the plug, clean the contacts, check
whether the strapping plug is plugged in
replace the empty report device
- 118 -
(dongle
box,
OGM
PLUS
OGM
PLUS
PLUS
in the pump software 1
OGM
PLUS
PLUS
in the pump software 2
Rev. 11-10.19
),