10.3.14.3 Batch / Input (only at E60 WITHOUT dongle plate)
The "Input" setting is used to determine which input (pulse input or metering lock) at plug II
of the pump should be used to evaluate the start pulse for the batch metering.
The start pulse cable connection depends on the selected input:
Input pulse:
Input metering lock:
10.3.14.4 Display in the operating display
10.4
Calibration
10.4.1
Overview
The procedure and display during the calibration process differ depending on whether or not
an oval gear meter is connected.
Fig. 10.44 calibration / Overview
417101799_EMP_IV_E60.docx
= plug II Pin
2+4
= plug II Pin
3+4
Fig. 10.42 Configuration / Batch / Input
Default setting = Metering lock
Pos.
Description
1
Operation mode
2
Quantity remaining to be metered
3
Strokes remaining to be executed
Fig. 10.43 Display in the operating display
see chapter
7.2.4.5
„Installing the batch function".
In this case, the original function
(e.g. pulse) can no longer be used.
NOTE
When using a dongle plate, a separate
input is available.
Calibration pump:
• see chapter
Calibration pump with oval gear
meter:
• see chapter
- 107 -
10.4.2
10.4.3
Rev. 11-10.19