Herunterladen Inhalt Inhalt Diese Seite drucken

ECOLAB Elados EMP IV E60 serie Betriebsanleitung Seite 67

Membran-dosierpumpe
Vorschau ausblenden Andere Handbücher für Elados EMP IV E60 serie:
Inhaltsverzeichnis

Werbung

Verfügbare Sprachen

Verfügbare Sprachen

Contents
1
General ..................................................................................................................... 70
1.1
EBS Numbers ................................................................................................................................................. 70
1.2
Transport damage .......................................................................................................................................... 72
1.3
Warranty coverage ......................................................................................................................................... 72
1.4
Contact address / Manufacturer...................................................................................................................... 72
2
Safety ....................................................................................................................... 73
2.1
Safety notes .................................................................................................................................................... 73
2.2
Emphases ....................................................................................................................................................... 73
2.3
Numberings .................................................................................................................................................... 73
2.4
Special safety notes for maintenance and repair work ................................................................................... 73
3
Delivery scope .......................................................................................................... 74
3.1
4
Functional description ............................................................................................. 75
4.1
Mechanical functions ...................................................................................................................................... 75
4.2
Electronic functions ......................................................................................................................................... 75
4.3
4.4
Operation mode .............................................................................................................................................. 75
5
Setup ........................................................................................................................ 76
5.1
Indicators / Controls / Jacks ............................................................................................................................ 76
6
Mounting .................................................................................................................. 77
6.1
Mounting diagram ........................................................................................................................................... 77
7
Device installation.................................................................................................... 78
7.1
Hydraulic installation ....................................................................................................................................... 78
7.1.1
Installation examples ......................................................................................................................................................... 78
7.1.2
Connecting the suction pipe and pressure pipe ................................................................................................................. 80
7.1.2.1
Suction and metering line connection with hose nipple ...................................................................................................... 80
7.1.2.2
Suction & metering line connection with insertion part in case of permanent tubing ........................................................... 80
7.1.2.3
Suction and metering line connection with tapered part ..................................................................................................... 81
7.2
Electrical connection ....................................................................................................................................... 81
7.2.1
Power supply ..................................................................................................................................................................... 81
7.2.2
Overview Control Board ..................................................................................................................................................... 82
7.2.3
Terminal board diagram ..................................................................................................................................................... 82
7.2.4
Connector Assignments Terminal X1 ................................................................................................................................. 83
7.2.4.1
7.2.4.1.1
7.2.4.2
Installing the pulse control (water meter) ........................................................................................................................... 84
7.2.4.3
Installing the standard signal control .................................................................................................................................. 84
7.2.4.4
Installing the control via the metering lock ......................................................................................................................... 84
7.2.4.5
Installing the batch function ............................................................................................................................................... 85
7.2.4.6
Installation stroke signal .................................................................................................................................................... 85
7.2.5
Connector Assignments Terminal X2 ................................................................................................................................. 85
7.2.5.1
Installation diaphragm burst detector ................................................................................................................................. 86
7.2.5.2
Installation metering monitoring ......................................................................................................................................... 86
7.2.6
Connector Assignments Terminal X3 ................................................................................................................................. 86
7.2.6.1
Installation low-level warning and fault ............................................................................................................................... 86
7.2.6.2
Hardware migration for alarm contact ................................................................................................................................ 87
7.2.6.2.1
7.2.6.2.2
7.2.7
Connector Assignments Terminal X4 ................................................................................................................................. 87
8
8.1
8.1.1
8.1.2
9
Startup ...................................................................................................................... 89
9.1
Switching on / off the pump ............................................................................................................................ 89
9.2
Venting the metering pump ............................................................................................................................. 89
9.3
Key- / switch functions .................................................................................................................................... 89
9.4
Description of display symbols........................................................................................................................ 90
9.5
Initial startup / Delivery status ......................................................................................................................... 90
9.5.1
Software version display .................................................................................................................................................... 91
9.5.2
Display at operating level ................................................................................................................................................... 91
9.5.3
Configuration ..................................................................................................................................................................... 91
417101799_EMP_IV_E60.docx
................................................................................................ 74
................................................................................... 75
..................................................................................................................... 88
.................................................................................................................. 88
at Dongle-plate) ....................................................................................... 88
- 67 -
.................................................... 88
PLUS
83
87
87
Rev. 11-10.19

Quicklinks ausblenden:

Werbung

Inhaltsverzeichnis
loading

Diese Anleitung auch für:

Elados emp iv e60Elados emp iv e60 plus

Inhaltsverzeichnis