10.3.13.5 Metering monitoring / Input (only at E60 WITHOUT dongle plate)
The "Input" setting is used to determine which input (pulse input or metering lock) at plug II
of the pump should be used to evaluate the incoming pulses from the metering monitoring
unit.
The flow monitor connection depends on the selected input:
Input pulse:
Input metering lock:
This function can only be selected if no dongle plate is connected.
NOTE
In this case, the original function (e.g. pulse input) can no longer be used.
10.3.13.6 Oval gear meter pulse display (only E60
10.3.14 Configuration / Batch
NOTE
The pump must be calibrated before using batch metering (see chapter
When activating batch mode with a signal to the metering lock/pulse input, a previously
defined quantity is metered with 100 % stroke frequency. The batch metering can be
interrupted by activating the metering lock or switching off the pump.
10.3.14.1 Selecting
417101799_EMP_IV_E60.docx
= plug II Pin
2+4
see chapter
= plug II Pin
3+4
monitoring".
This display shows the number of pulses recorded
Fig. 10.39
during the last calibration process (running time
during calibration = 1 min).
If the value shown is less than 60, metering
monitoring using an oval gear meter is only
possible to a limited extent.
- 105 -
7.2.5.2
„Installation metering
Fig. 10.38 Configuration / Metering monitoring / Input
PLUS
)
Fig. 10.40 Configuration / Batch / Selecting
-
Batch is inactive
(Default setting)
Batch is active
✓
If batch metering is active, the
following items appear in the
submenu:
Menu item
• Quantity
• Input
10.4
"Calibration").
see chapter
10.3.14.2
10.3.14.3