7.2.4

Connector Assignments Terminal X1

Fig. 7.17
Connector assignment
terminal X1
7.2.4.1
Connector assignments of Slot I (3-terminal)
input for low-level advance warning and empty report

7.2.4.1.1 Installing the suction pipe with low-level advance warning and empty report

Slot I must always be assigned, either through the mounted strapping plug (protective cap
NOTE
with corresponding symbol; see chapter
Fig 5.3, Pos. 11) or through connection to the empty report device.
417101799_EMP_IV_E60.docx
Conductor
Coloring
Terminal
(cable connection)
1
brown
2
blue
3
black
4
5
6
7
8
9
10
11
12
Conductor
Terminal
coloring
(cable connection)
1
brown
2
blue
3
black
(plug assignments: see also chapter
low-level advance warning (3 terminal) ")
Fig. 7.18
Connector assignment of slot I
5.1
"Indicators / Controls / Jacks",
1
+
3
= Input low-level advance warning
Switch contact low-level advanced warning open:
low-level advanced warning active (invertible circuit
logic, see chapter
10.3.8
contact"), empty report symbol on display flashes, pump
is not locked.
Terminal Assignment
1
Relay input low-level advance warning
GND ( ┴ )
3
2
+
3
= Input empty report
Switch contact empty report open:
empty report active (invertible circuit logic, see chapter
10.3.8
"Configuration / Low-level contact"), empty report
symbol on display appears, pump is locked.
Terminal Assignment
2
Relay input empty report
GND ( ┴ )
3
Fig. 7.19
Installing the suction pipe with low-level advance warning
and empty report
- 83 -
Assignment
Input low-level advance warning
Input empty report
GND (reference potential)
Input batch function
Output 5 V, DC
(loadable with max. 100 mA)
Input pulse control
GND (reference potential)
Input metering lock
Input standard signal 0/4..20 mA (+)
Input standard signal 0/4..20 mA (–)
Output stroke signal (+)
Output stroke signal (–)
Assignment
Input low-level advance warning
Input empty report input
GND ( ┴ )
14.5.1
"Connector assignments:
"Configuration / Low-level
Rev. 11-10.19

Quicklinks ausblenden:

Werbung

Inhaltsverzeichnis
loading

Diese Anleitung auch für:

Elados emp iv e60Elados emp iv e60 plus

Inhaltsverzeichnis