10.4.4

Calibration / Manual

If the calibration value to be entered is known, a "dry calibration" (immediate entry of the
value without a previous calibration process) can be conducted.
However, this method is not very accurate as no consideration is given to the on-site
conditions (back-pressure, viscosity, cable cross-chapters and lengths etc).
Fig. 10.50 Calibration / Manual
10.4.4.1

Calibration data table

The pump capacity in l/h is allocated to the pump's electronics on the basis of the calibration
values entered in the table.
Example:
A specified value of 2.33 l results in a pump capacity of 140 l/h.
NOTE
These values relate to the metering medium of water at 20°C
Pump
Fig. 10.51 EMP IV
10.5

Operating data

The following operating data is recorded and displayed under this menu item:
Operating hours
Liter
Amount of plulses
417101799_EMP_IV_E60.docx
Pump capacity [l/h]
140
210
450
630
750
- 110 -
Pump calibration value [l]
2.33
3.50
7.50
10.5
12.5
Rev. 11-10.19