10.3.12.2 Display in the operating display with an active metering controller
Fig. 10.30 Downward divergence
Fig. 10.31 No divergence
Fig. 10.32 Upward divergence
Fig. 10.33 E60++
NOTE
10.3.13 Configuration / Metering monitoring
If the metering monitoring function is enabled, the pump strokes are compared to the
incoming pulses using a connected external metering monitor (e.g. oval gear meter). If a
configurable tolerance threshold is breached, an alarm is triggered.
If an oval gear meter is connected as a metering monitoring unit and should be
correspondingly evaluated, then the configuration/oval gear meter function must be
NOTE
enabled in addition to the configuration/metering monitoring function
(see chapter
10.3.13.1 Selecting
417101799_EMP_IV_E60.docx
▼ = Downward metering divergence
The pump is currently delivering less than the preset stroke
frequency (here 100/min for example) requires.
Metering frequency is increased automatically until the actual
value matches the target value.
- = No metering divergence
The pump delivers exactly the preset flow (here 100/min for
example).
No correction is necessary.
▲ = Upward metering divergence
The pump is currently delivering more than the preset stroke
frequency (here 100/min for example) requires.
Metering frequency is reduced automatically until the actual value
matches the target value.
Dongle plate mounted.
Oval gear meter OGM
10.3.11
"Configuration / Oval gear meter (only E60
- 103 -
mounted.
PLUS
PLUS
& OGM or OGM
Fig. 10.34 Configuration / Metering monitoring / selecting
-
metering monitoring is inactive.
(Default setting)
✓ metering monitoring is active.
On activating metering monitoring, a
submenu appears with the following
menu items:
Menu item
• Stop pump
• Strokes
• Deviation
• Input
PLUS
)").
see chapter
10.3.13.2
10.3.13.3
10.3.13.4
10.3.13.5
Rev. 11-10.19