Metering rates

The reproducible metering accuracy is approx. ± 3 % at a minimum 30% stroke length under
invariable conditions.
Due to the characteristics of the pump, higher output can be produced until the operating
temperature is reached.
Accurate metering can be achieved by observing the following points:
a) All metering output data refer to measurements with water at 20 °C as well as a constant
supply voltage and a warmed-up operating condition of the metering pump.
b) If there is pre-pressure on the suction side, the pressure difference between the suction
and the pressure sides must be at least 0.1 MPa (1 bar). The water column on the
metering pump must be protected by an appropriate valve arrangement.
A pressure maintaining valve or a metering value is not an absolutely hermetically sealing
NOTE
shutoff device.
Metering stroke adjustment may only be performed with the pump running if the stroke
WARNING
adjusting screw is enabled.
14.7

Delivery capacity depending on the backpressure and stroke setting

Setting accuracy + 15 % - 5 % of the nominal value; all data relate to water at 20 °C and
comply with the notes in the operating instructions.
14.7.1

Delivery capacity type 01400 / 1 MPa (10 bar)

Fig. 14.3 Delivery capacity type 01400 / 1 MPa (10 bar)