Operating faults

12.1

Metering warning messages (display)

Display
Meaning
reserve report
(flashing)
Fig. 12.1
empty report
Fig. 12.2
metering lock
(only possible if this is
configured)
Fig. 12.3
Indicator in operation
mode 4..20 mA flashes
standard signal
monitoring responds
Fig. 12.4
standard signal is above
--.-
23.0 mA
Fig. 12.5
12.2

Error messages (display and Fault-LED)

NOTE
Appearing alarm messages can be quit by pressing the Start/Stop button.
Display
alarm
failure 1
permanent stroke
Fig. 12.6
alarm
failure 2
no stroke
Fig. 12.7
alarm
failure 3
motor control
Fig. 12.8
error in evaluating the
alarm
metering monitoring or
failure 4
oval gear meter
oval gear meter
Fig. 12.9
Diaphragm burst sensor
alarm
has detected a leckage
failure 5
diaphragm burst
Fig. 12.10 Operating faults: Error Messages (Display) Failure 5
alarm
failure 9
dongle box
not found
Fig. 12.11 Operating faults: Error Messages (Display) Failure 9
alarm
failure 10
OGM PLUS
not found
Fig. 12.12 Operating faults: Error Messages (Display) Failure 10
alarm
failure 12
Communication
Dongle Box
Fig. 12.13 Operating faults: Error Messages (Display) Failure 12
417101799_EMP_IV_E60.docx
Effect
pump continues
running
Operating faults: Metering warning messages (display): Reserve report
pump is stopped
Operating faults: Metering warning messages (display): Empty report
pump is stopped
Operating faults: Metering warning messages (display): Metering lock
pump is stopped
Operating faults: Metering warning messages (display): Standard signal monitoring
pump runs in
continuous
operation
Operating faults: Metering warning messages (display): Standard signal above 23 mA
Bedeutung

Auswirkung

Motor is running out of
over dosage
control
Operating faults: Error Messages (Display) Failure 1
Motor is not running
despite of rotating
no metering
dosing symbol.
Operating faults: Error Messages (Display) Failure 2
motor in continuous
continuous
operation without
metering
request
Operating faults: Error Messages (Display) Failure 3
pump meters too
little or too much
Operating faults: Error Messages (Display) Failure 4
Metering head has
a leckage
A dongle box which was
connected previously is
not detected the next
Pump is being
time the pump is
stopped
switched on
An OGM
which was
Plus
connected previously
is not detected the
Pump is being
next time the pump is
stopped
switched on
No comunication
between DongleBox
Pump is being
Box and pump
stopped
Cause
low-level advance
warning active
empty report active
no external enable of
the pump
standard signal is under
3 mA or cable to
standard signal
connection is broken
standard signal exceeds
the display range
Ursache
Power electronic failure
backpressure too high
valve closed at pressure
side
Motor overheated/damaged cool of the motor, or. change
power electronic failure
optical sensor polluted
PC-board fault
Plug connection from gear
to PC-Board interrupted
tube fault
diaphragm fault
backpressure too high or
too low
Metering head loose
(leaking)
Diaphragm wrenched
Connection between
DongleBox and pump
interrupted
Connection between OGM
PLUS and DongleBox
interrupted
Transmission of data from
the dongle box to the
pump has been disrupted
during operation
- 116 -
Remedy
Refill the metering medium
Refill the metering medium
Activate external enable or deactivate
the metering lock in the configuration
menu (see chapter
10.3.7
"
Configuration / Metering lock").
check the standard signal or cable
reduce the standard signal
Behebung
replace PC-Board
reduce pressure
open valve
replace PC-board
send in pump
control optical sensor
connection
check the tubes
check the diaphragm
check the backpressure
Fix the screws of metering
head diagonal
Change diaphragm
Restore the connection
between the pump and the
dongle box, or disable the
dongle box in the software
(see chapter
Fehler!
Verweisquelle konnte nicht
gefunden
werden.)
Restore the connection
between the dongle box and
OGM
Plus
, or disable the dongle
box in the software
(see chapter
Fehler!
Verweisquelle konnte nicht
gefunden
werden.)
Check the connection between
the pump and the dongle box,
and replace the dongle box if
necessary
Rev. 11-10.19