Herunterladen Inhalt Inhalt Diese Seite drucken

Selecting; Setting; Configuration / Autostart; Configuration / Metering Lock - ECOLAB Elados EMP IV E60 serie Betriebsanleitung

Membran-dosierpumpe
Vorschau ausblenden Andere Handbücher für Elados EMP IV E60 serie:
Inhaltsverzeichnis

Werbung

Verfügbare Sprachen

Verfügbare Sprachen

10.3.5.1

Selecting

10.3.5.2

Setting

10.3.6

Configuration / Autostart

This function determines whether the pump is set to "OFF" ("Standby" in V 3.5) when the
mains connection is re-established following a power cut or if the pump should immediately
recommence functioning in the configured operation mode.
10.3.6.1
Selecting
10.3.7

Configuration / Metering lock

If the metering lock is enabled, the pump only functions if an external enable contact is
connected to plug II between PINS 3+4 (see chapter
metering lock") (regardless of which operation mode is set).
417101799_EMP_IV_E60.docx
Fig. 10.18 Code / Unit / selecting
- Code query inactive.
(Default setting)
✓ Code query active.
see chapter
Fig. 10.19 Configuration / Unit / setting
Fig. 10.20 Configuration / Autostart / selecting
-
autostart ist inactive.
When the mains voltage is applied,
the pump always enters the "OFF"
("Standby" in V 3.5) operating state.
(Default setting)
autostart ist active.
When the mains voltage is connected,
the pump starts functioning in the
configured operation state.
7.2.4.4
"Installing the control via the
- 99 -
10.3.5.2
Rev. 11-10.19

Quicklinks ausblenden:

Werbung

Inhaltsverzeichnis
loading

Diese Anleitung auch für:

Elados emp iv e60Elados emp iv e60 plus

Inhaltsverzeichnis