Upgrading the EMP IV E60 to the EMP IV E60
To upgrade the
functions, obtain the additional dongle-plate from our range of accessories.
(Article no. 249629, EBS-No. on request).
For installation of the dongle-plate, please open the housing as shown in
chapter
7.2.2
8.1
Fitting the Dongle-plate E60
Open the screw closures of Pos.
Insert the dongle plate (Pos. 1) into the now open connector of Pos.
Close the screw closures of Pos.
8.1.1
Connector Assignments Dongle-Plate E60
Conductor coloring
Pos.
(cable connection)
25
26
27
28
29
Free for future use
30
8.1.2
Installation Oval Gear Meter (OGM or OGM
The oval gear meter function must be activated in menu first.
NOTE
If a OGM
(see chapter
417101799_EMP_IV_E60.docx
EMP IV E60
to the
"Overview Control Board".
PLUS
Pos
Description
X2
Terminal X2
1
Dongle-plate
Install the dongle-plate (Pos. 1) on the terminal (Pos. X2) on
the mainboard. Use the slots, Pos.
Fig. 8.1
Fitting the Dongle-Plate
Description
brown
Output 5 V
white
Bus line
black
Pulse input
blue
GND
Plus
is attached, the function oval gear meter is activated automatically.
10.3.11
„Configuration / Oval gear meter (only E60
EMP IV E60
and thus access the additional
PLUS
19
to
24.
19
to
24
in order to fix the dongle plate in place.
PLUS
Connection OGM
at Dongle-plate)
PLUS
25
+
26
+
Terminal Assignment
25
26
27
28
Fig. 8.3
Installation Oval Gear Meter
- 88 -
PLUS
19
to 24. (Pos. 2).
19-24
Fig. 8.2
Dongle-Plate
PLUS
PLUS
& OGM or OGM
27
+
28
Anschluss OGM
Output 5 V DC
Bus line
Relay input pulse
GND ( ┴ )
(Pos. 2).
PLUS
)").
PLUS