10.3.12.2

Display in the operating display with an active metering controller

Fig. 10.30 Display in the operating display with an active metering controller: Downward metering divergence
Fig. 10.31 Display in the operating display with an active metering controller: no metering divergence
Fig. 10.32 Display in the operating display with an active metering controller: Upward metering divergence
NOTE
Fig. 10.33 Mounting note

10.3.13 Configuration / Metering monitoring

If the metering monitoring function is enabled, the pump strokes are compared to the
incoming pulses using a connected external metering monitor (e.g. oval gear meter). If a
configurable tolerance threshold is breached, an alarm is triggered.
The metering monitoring system can be connected at plug II (or plug V if a dongle box is
used) at Pin
2+4
chapter
10.3.13.5
electrical connection see chapter
chapter
8.2.1.1
If an oval gear meter is connected as a metering monitoring unit and should be
correspondingly evaluated, then the configuration/oval gear meter function must be
NOTE
enabled in addition to the configuration/metering monitoring function
(see chapter
PLUS
10.3.13.1

Selecting

417101441_EMP_III_E60.docx
▼ = Downward metering divergence
The pump is currently delivering less than the preset stroke frequency
(here 100/min for example) requires.
Metering frequency is increased automatically until the actual value
matches the target value.
- = No metering divergence
The pump delivers exactly the preset flow (here 100/min for example).
No correction is necessary.
▲ = Upward metering divergence
The pump is currently delivering more than the preset stroke frequency
(here 100/min for example) requires.
Metering frequency is reduced automatically until the actual value
matches the target value.
Dongle-box

Oval gear meter

(input pulse) or at Pin
"Metering monitoring / Input (only at
7.2.4.5
"Installation oval gear meter
"Configuration / Oval gear meter (only
10.3.11
)").
mounted.
PLUS
OGM
3+4
(input metering lock) (assortment of inputs see
E60
WITHOUT
"Installing the metering monitoring" and
(OGM
PLUS
or
OGM
Fig. 10.34 Configuration / Metering monitoring: Selecting
-
metering monitoring is inactive.
(Default setting)
✓ metering monitoring is active.
On activating metering monitoring, a
submenu appears with the following
menu items:
Menu item
• Stop pump
• Strokes
• Deviation
• Input
- 106 -
mounted.
Dongle
box)",
").
PLUS
E60
&
OGM
or
OGM
Chapter
10.3.13.2
10.3.13.3
10.3.13.4
10.3.13.5
Rev. 12-08.18