c. Once the unit is in place, check and readjust the levelness as necessary.

GAS CONNECTION

Your fryer will give you peak performance when the gas supply line is of sufficient size to provide the correct gas flow.
The gas line must be installed to meet the local building codes or National Fuel Gas Codes. Gas line sizing requirements
can be determined by your local gas company by referring to National Fuel Gas Codes. The gas line needs to be large
enough to supply the necessary amount of fuel to all appliances without losing pressure to any appliance.
NEVER supply the fryer with a gas that is not indicated on the data plate. Using the incorrect gas type will
cause improper operation. If you need to convert the fryer to another type of fuel, contact your dealer.
Fuel Types - Each fryer is equipped to work with one type of fuel. The type of fuel with which the appliance is intended
to operate is stamped on the data plate attached to the inside of the door.
NEVER use an adaptor to make a smaller gas supply line fit the cooker connection.
This may not allow proper gas flow for optimum burner operation, resulting in poor
cooker performance.
Quick Disconnect Gas Connection
Gas fryers equipped with casters must be installed with connectors that comply with the Standard for Connectors for
Movable Gas Appliances. This connection should include a quick disconnect device that complies with the Standard
for Quick Disconnect Devices for Use With Gas Fuel. When installing a quick disconnect you must also install a means
for limiting the movement of the fryer. This device will prevent the gas line or the quick disconnect from being strained.
The restraining device should be attached to the cooker on the back panel.
Fuel Supply Line Leak and Pressure Testing
The fuel supply system must be tested before the fryer is used. If the fuel line is going to be tested at a pressure greater
than (>)1/2 PSIG (3.45 kPa), make sure that the fryer is disconnected from the fuel line. If the fuel line is to be tested
at a pressure equal to or less than (<) 1/2 PSIG (3.45 kPa), the fryer can be connected but the unit's gas valve must be
shut. Test all gas line connections for leaks with a solution of soap and water when pressure is applied.
Gas pressure check
Gas pressure should be measured at the burner manifold and should match the pressure requirement
listed on the data plate mounted on the inside of the fryer door.

ELECTRICAL CONNECTION

The electrical service used by the fryer must comply with local codes and regulations. The power requirements for the
fryer are shown below.
Input Voltage
Current per fryer
Filter System
The fryer must be grounded in accordance with local code and regulations. It is advised that this power supply be plugged
into a wall receptacle that is controlled by the ventilation control. This will prevent the fryer from being operated without
the ventilator on.
WARNING
NOTICE
North America
120 VAC, 60Hz
0.5 Amps
7.0 Amps
5
International
220, 230, (or 240) VAC, 50Hz
0.5 Amps
4.0 Amps