Herunterladen Inhalt Inhalt Diese Seite drucken

Aventics HF03 Betriebsanleitung Seite 59

Vorschau ausblenden Andere Handbücher für HF03:
Inhaltsverzeichnis

Werbung

Verfügbare Sprachen
  • DE

Verfügbare Sprachen

  • DEUTSCH, seite 1
Input assignment in the
8-position input module
and the 4-position
input/output module
Input assignments in the
16-position input module
AVENTICS | HF03/HF02 | 1987765493–BDL–001–AB
Table 5:
Input assignment in the 8-position input module and the
4-position input/output module
Pin
Signal
1
P24V
2
3
PGND
4
Input
5
1)
On the 8-position input modules, pin 4 of inputs 4 to 7 is bridged to pin 2 of
inputs 0 to 3. Therefore, 2 separate inputs are available on all sockets of inputs
0-3. For example, antivalent sensors can be connected here. the socket of the
mechanically unoccupied inputs must be closed with a plug. When input 0 is
occuppied, input 4 should be closed, when input 1 is occupied, input 5 should be
closed, etc. (see figure below).
0 ... 3
Table 6:
Input assignments in the 16-position input module
Pin
Signal
1
P24V
2
Input
1, 3, 5, 7, 9, 11, 13, 15
3
PGND
4
Input
0, 2, 4, 6, 8, 10, 12, 14
5
Installation
Assignment
Sensor supply
1)
Not connected
Ground for P24V
Sensor signal
Not connected
4 ... 7
Assignment
Sensor supply
Sensor signal
Ground for P24V
Sensor signal
Not connected
59

Werbung

Inhaltsverzeichnis
loading

Diese Anleitung auch für:

Hf02

Inhaltsverzeichnis