Herunterladen Inhalt Inhalt Diese Seite drucken

Adjustment Of Staring Injection Amount; Checking The Injection Stop - Takeuchi TB 175 Handbuch

Vorschau ausblenden Andere Handbücher für TB 175:
Inhaltsverzeichnis

Werbung

4.3.5. Adjustment of Staring Injection Amount

4.3.6. Checking the Injection Stop

Leave the regulator lever at the position as before.
① Set the engine speed at the starting injection amount adjust
speed and leave the regulator lever at the position in 2
above.
② Screw in the starting injection amount adjust bolt and adjust
it to obtain the specified injection amount.
③ Set the pump speed at 50 min
exceeding the specifications is being injected.
① Checking the Injection Stop: Set the pump speed at the
speed 50min-1 higher than the no load max. speed, and
check that the injection amount reduces to zero.
② Checking the Stopping: Set the pump speed at the rated
speed, turn off the stop solenoid and check that the
injection amount reduces to zero.
48
-1
and check that the amount

Quicklinks ausblenden:

Werbung

Kapitel

Inhaltsverzeichnis
loading

Inhaltsverzeichnis