3. Disassembly ,Reassembly
and Inspection
3.1. Disassembly
Disassembled parts must be put aside in order.
Wash them before reassembly.
3.1.1. Separating the pump body from the
governor body
Install the pump body to the disassembly table.
Remove the link lifter fix bolt.
Turn the link lifter plate counterclockwise.
Rotating the link lifter will move the inside link
upward/downward, so the control rack may be
engaged/disengaged.
Remove the bolt fixing the pump and governor bodies.
Separate the governor from the pump body.
The pump body separated from t he governor body
22
Link insertion window