Herunterladen Diese Seite drucken

MICRO-EPSILON confocalDT IFD2410 Betriebsanleitung Seite 173

Vorschau ausblenden Andere Handbücher für confocalDT IFD2410:

Werbung

Name
ME-Bus name
Type
1 Comp 1 type
Name
1 Comp 1 name
Signal1
1 Comp 1 sig1
Signal2
1 Comp 1 sig2
Factor1
1 Comp 1 fac 1
Factor2
1 Comp 1 fac 2
Offset
1 Comp 1 offs
Parameter
1 Comp 1 param
Available signals part 0
1 Comp 1 avs 0
Available signals part 1
1 Comp 1 avs 1
Available signals part 2
1 Comp 1 avs 2
Available signals part 3
1 Comp 1 avs 3
Available signals part 4
1 Comp 1 avs 4
Available signals part 5
1 Comp 1 avs 5
Type
1 Comp 2 type
Name
1 Comp 2 name
Signal1
1 Comp 2 sig1
Signal2
1 Comp 2 sig2
Factor1
1 Comp 2 fac 1
Factor2
1 Comp 2 fac 2
Offset
1 Comp 2 offs
Parameter
1 Comp 2 param
Available signals part 0
1 Comp 2 avs 0
Available signals part 1
1 Comp 2 avs 1
Available signals part 2
1 Comp 2 avs 2
Available signals part 3
1 Comp 2 avs 3
Available signals part 4
1 Comp 2 avs 4
Available signals part 5
1 Comp 2 avs 5
Type
1 Comp 3 type
Name
1 Comp 3 name
ASCII command
ID
Data type
54150
comp ch01 2 type
UINT8
54151
comp ch01 2 name
CHAR(32)
54153
comp ch01 2 signal1
CHAR(32)
54154
comp ch01 2 signal2
CHAR(32)
54162
comp ch01 2 factor1
FLOAT
54163
comp ch01 2 factor2
FLOAT
54166
comp ch01 2 offset
FLOAT
54167
comp ch01 2 parameter
UINT32
54199
meta_comp ch01 2
CHAR(235)
54200
meta_comp ch01 2
CHAR(235)
54201
meta_comp ch01 2
CHAR(235)
meta_comp ch01 2
54202
CHAR(235)
54203
meta_comp ch01 2
CHAR(235)
54204
meta_comp ch01 2
CHAR(235)
54250
comp ch01 3 type
UINT8
54251
comp ch01 3 name
CHAR(32)
54253
comp ch01 3 signal1
CHAR(32)
54254
comp ch01 3 signal2
CHAR(32)
54262
comp ch01 3 factor1
FLOAT
54263
comp ch01 3 factor2
FLOAT
54266
comp ch01 3 offset
FLOAT
comp ch01 3 parameter
54267
UINT32
54299
meta_comp ch01 3
CHAR(235)
54300
meta_comp ch01 3
CHAR(235)
54301
meta_comp ch01 3
CHAR(235)
54302
meta_comp ch01 3
CHAR(235)
54303
meta_comp ch01 3
CHAR(235)
54304
meta_comp ch01 3
CHAR(235)
54350
comp ch01 4 type
UINT8
54351
comp ch01 4 name
CHAR(32)
IFD241x PROFINET Module Documentation | Micro-Epsilon
Unit
Access
Min value
Max value
None
read-write
0
8
None
read-write
0
32
None
read-write
0
32
None
read-write
0
32
None
read-write
-3,40E+48
3,40E+48
None
read-write
-3,40E+48
3,40E+48
mm
read-write
-2147.0
2147.0
None
read-write
2
32767
None
read-only
0
235
None
read-only
0
235
None
read-only
0
235
None
read-only
0
235
None
read-only
0
235
None
read-only
0
235
None
read-write
0
8
None
read-write
0
32
None
read-write
0
32
None
read-write
0
32
None
read-write
-3,40E+48
3,40E+48
None
read-write
-3,40E+48
3,40E+48
mm
read-write
-2147.0
2147.0
None
read-write
2
32767
None
read-only
0
235
None
read-only
0
235
None
read-only
0
235
None
read-only
0
235
None
read-only
0
235
None
read-only
0
235
None
read-write
0
8
None
read-write
0
32
Choices
(0, 'None'),(1, 'Moving'),(2, 'Recursive'),
(3, 'Median'),(4, 'Calc'),(7, 'Thickness'),(8,
'Copy')
(0, 'None'),(1, 'Moving'),(2, 'Recursive'),
(3, 'Median'),(4, 'Calc'),(7, 'Thickness'),(8,
'Copy')
(0, 'None'),(1, 'Moving'),(2, 'Recursive'),
(3, 'Median'),(4, 'Calc'),(7, 'Thickness'),(8,
'Copy')
IFD2410 2411 2415
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x

Werbung

loading