Herunterladen Diese Seite drucken

MICRO-EPSILON confocalDT IFD2410 Betriebsanleitung Seite 162

Vorschau ausblenden Andere Handbücher für confocalDT IFD2410:

Werbung

Name
ME-Bus name
Device type
Device type
Device name
Device name
Hardware version
Hw version
Software version
Sw version
Actual user
Actual user
Login
Login
Logout
Logout
User level when restarting
Default user
Password old
Password old
Password new
Password new
Password repeat
Passwd repeat
Name
Device name
Serial number
Serial num
Option number
Option number
Article number
Article number
Dark correction start
Dark start 1
Dark correction state
Dark status 1
Read
Basic read
Store
Basic store
Set default
Basic default
Mode
Preset mode
List
Preset list
Named read
Preset read
Current
Meas current
Named read
Meas read
Named store
Meas store
Named delete
Meas delete
Initial
Meas initial
List
Meas list
Set default
Meas default
Error number
Error number
Error description
Error descrip
Reboot sensor
Reset
Factory reset
Factory reset
ASCII command
ID
Data type
50001
_netx_standard device_type
UINT32
getinfo
50002
CHAR(32)
50003
getinfo
CHAR(32)
50004
getinfo
CHAR(32)
50500
getuserlevel
UINT8
50501
login
CHAR(32)
50502
logout
BIT
50503
stduser
UINT8
50504
passwd
CHAR(32)
50505
passwd
CHAR(32)
50506
passwd
CHAR(32)
50550
getinfo
CHAR(34)
50554
getinfo serial
CHAR(38)
50555
sensor_option
CHAR(10)
50557
getinfo
CHAR(38)
darkcorr_ch01 start
50600
BIT
darkcorr_ch01 status
50602
UINT32
50650
basicsettings read
BIT
50651
basicsettings store
BIT
50652
setdefault basicsettings
BIT
50700
meassettings presetmode
UINT8
50701
meassettings presetlist
CHAR(235)
50702
preset read
CHAR(32)
50750
meassettings current
CHAR(32)
50751
meassettings read
CHAR(32)
50752
meassettings store
CHAR(32)
50753
meassettings delete
CHAR(32)
50754
meassettings initial
CHAR(32)
50755
meassettings list
CHAR(235)
50756
setdefault meassettings
BIT
sensor_error number
50800
UINT16
50801
sensor_error description
CHAR(235)
50850
reset
BIT
50900
setdefault all
BIT
IFD241x PROFINET Module Documentation | Micro-Epsilon
Unit
Access
Min value
Max value
None
read-only
0
4294967295
None
read-only
0
32
None
read-only
0
32
None
read-only
0
32
None
read-only
1
4
None
write-only
0
32
None
write-only
True
True
None
read-write
1
2
None
write-only
0
32
None
write-only
0
32
None
write-only
0
32
None
read-only
0
34
None
read-only
0
38
None
read-only
0
10
None
read-only
0
38
None
write-only
True
True
None
read-only
0
100
None
write-only
True
True
None
write-only
True
True
None
write-only
True
True
None
read-write
1
3
None
read-only
0
235
None
write-only
0
32
None
read-only
0
32
None
write-only
0
32
None
write-only
0
32
None
write-only
0
32
None
read-write
0
32
None
read-only
0
235
None
write-only
True
True
None
read-only
0
65535
None
read-only
0
235
None
write-only
True
True
None
write-only
True
True
Choices
(1, 'User'),(3, 'Professional'),(4, 'Professional+')
(1, 'Logout')
(1, 'User'),(2, 'Professional')
(1, 'Start')
(0, 'Ready'),(1, 'Busy'),(100, 'Failure')
(1, 'Read')
(1, 'Store')
(1, 'Set default')
(1, 'Static'),(2, 'Balanced'),(3, 'Dynamic')
(1, 'Set default')
(1, 'Reset')
(1, 'Factory reset')
IFD2410 2411 2415
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x

Werbung

loading