en
External interfaces
SSM relay
SBM relay
Control input
Fig. 63: External interfaces menu
SBM relay
SBM relay function
SBM relay
forced control
Fig. 64: Menu SBM-relay
SBM relay function
Motor running
Mains voltage present
Ready for operation
Fig. 65: SBM relay function menu
12.5

SBM relay forced control

176
Universal
1.0
1.3
1.3.6
1.3.6.3
1.3.6.3 / 1
1.3.6.3 / 2
1.3.6.3 / 3
1
Only appears if twin-head pump is configured.
Possible settings:
Selection option
Motor running (factory setting)
Mains voltage present
Ready for operation
Table 24: Function SBM relay
SBM/EBM (collective run signal/individual run signal) in twin-head pump operation
SBM: The SBM contact can be assigned to any of the two pumps. Both contacts signal the
operating status of the twin-head pump in parallel (collective run signal).
EBM: The SBM function of the twin-head pump can be configured so that the SBM con-
tacts signal only operational messages of the respective pump (individual run signal). In
order to record run signals of both the pumps, both contacts must be assigned.
Universal
1.0
1.3
1.3.6
2
1.3.6.5
SBM
EBM
2
These sub-menus only appear when the twin-head pump is connected.
An SBM relay forced control is used as function test of the SBM relay and electrical connec-
tions.
To do this, select the following in the menu:
Universal
1.0
Installation and operating instructions • Wilo-Yonos GIGA2.0-I/-D • Ed.01/2023-03
Display text
Settings
External interfaces
SBM relay
1
SBM relay function
Motor running
Mains voltage present
Ready for operation
Function SBM relay
SBM relay connects when motor is running. Closed re-
lay: The pump is supplying.
SBM relay connects for power supply. Closed relay:
Voltage available.
SBM relay connects when there is no fault. Closed re-
lay: Pump can supply.
Display text
Settings
External interfaces
SBM relay
Twin-head pump
2
SBM relay function
System mode (SBM)
Single pump mode (EBM)
Display text
Settings