Warning message, warning code (W...)
Warnings indicate restricted pump function. The pump continues to operate in restric-
ted mode (emergency operation).
Depending on the cause of the warning, emergency operation leads to a restriction of
the control function and even reactivation of a fixed speed.
If the pump identifies as part of permanent monitoring that the cause of the warning no
longer applies, the warning is revoked and operation resumes.
If there is a warning message, the display is permanently on and the green LED indicator is
off.
The following table gives an overview of possible messages in the display:
Universal
Display text
Warning
Warning
Please check operating
Check the installation and operating instructions
manual
Double pump
Twin-head pump
This head
Location: This head
Partner head
Location: Partner head
Exists since:
Since
Acknowledge needed
Confirmation required
For acknowlege long
Press and hold the button for acknowledgement
press knob
Acknowleged, waiting for
Acknowledged, waiting for restart
restart
Reset energy counter
Reset energy counter
Press return key to cancel Press "Back" to cancel
Press and hold return key
Press and hold "Back" to cancel
to cancel
System Notification
System notification
no valid Parameter
No valid parameters
Production mode active
Production mode active
HMI blocked
Display blocked
Code
Warning
550
There is flow through the
pump in the opposite dir-
ection of flow.
Additional information about causes and remedy:
If flow passing through pump in the opposite direction is too strong, the motor
can no longer start.
551
Undervoltage
Additional information about causes and remedy:
The pump is running. Undervoltage reduces the pump's performance.
If the voltage continues to drop, reduced operation cannot be maintained.
552
There is externally gener-
ated flow through the
pump in the direction of
flow.
Additional information about causes and remedy:
The pump can start despite flow.
Installation and operating instructions • Wilo-Yonos GIGA2.0-I/-D • Ed.01/2023-03
Cause
Remedy
External influences
Check power control of the
cause flow against the
pumps,
direction of the
install swing check valve if
pump's flow.
needed.
Power supply too low.
Check power supply.
Power supply has
fallen below a min-
imum limit value.
External influences
Check power control of the
cause flow in the
other pumps.
pump's direction of
flow.