6.3

Safety

Installation and operating instructions • Wilo-Yonos GIGA2.0-I/-D • Ed.01/2023-03
DANGER
When dismantled, the permanent magnet rotor inside the pump can pose
mortal danger for people with medical implants (e.g. pacemakers).
• Follow the general behavioural guidelines that apply to handling elec-
trical devices!
• Do not open the motor!
• Dismantling and installation of the rotor may only be carried out by
Wilo customer service! If you have been fitted with a pacemaker, you
must not carry out this kind of work!
DANGER
Risk of fatal injury due to lack of protective devices!
Due to missing protective devices of the electronic module or in the
range of the coupling/motor, electric shock or contact with rotating parts
can lead to life-threatening injuries.
• Before commissioning, safety devices such as such as electronic mod-
ule covers or coupling covers that were removed must be reinstalled!
DANGER
Potentially fatal injury due to electronic module not being in-
stalled!
A life-threatening voltage may be present at the motor contacts!
Normal operation of the pump is only permitted with the electronic
module installed.
• Never connect or operate the pump without the electronic module
mounted!
DANGER
Risk of fatal injury from falling parts!
The pump itself and pump parts can be extremely heavy. Falling parts
pose a risk of cuts, crush injuries, bruises or impacts, which can be fatal.
• Always use suitable lifting equipment and secure parts against falling.
• Never stand underneath a suspended load.
• During storage and transport, as well as before all installation and as-
sembly work, ensure that the pump is in a safe position and standing
securely.
WARNING
Personal injury due to strong magnetic forces!
Opening the motor leads to high, abruptly occurring magnetic forces.
This can lead to serious cuts, crushing injuries and bruises.
• Do not open the motor!
WARNING

Hot surface!

The entire pump can become very hot. There is a risk of burns!
• Allow the pump to cool down before commencing any work!