2.4

Transport

2.5

Installing/dismantling

118
DANGER
When dismantled, the permanent magnet rotor inside the pump can pose
mortal danger for people with medical implants (e.g. pacemakers).
• Follow the general behavioural guidelines that apply to handling elec-
trical devices!
• Do not open the motor!
• Dismantling and installation of the rotor may only be carried out by
Wilo customer service! If you have been fitted with a pacemaker, you
must not carry out this kind of work!
NOTICE
The magnets inside the motor do not pose a danger provided the motor
is completely assembled. Persons with pacemakers can approach the
pump without restrictions.
Wear protective equipment:
safety gloves for protection against cuts
safety shoes
sealed safety goggles
safety helmet (when using lifting equipment)
Only use legally specified and approved lifting gear.
Select the lifting gear based on the prevailing conditions
(weather, attachment point, load etc.).
Always attach the lifting gear to the designated attachment
points (lifting eyes).
Position the lifting equipment in a way that ensures stability
during use.
When using lifting equipment, a second person must be
present to coordinate the procedure if required (e.g. if the op-
erator's field of vision is blocked).
Persons must not stand underneath suspended loads. Do not
move loads over workplaces where people are present.
Wear protective equipment:
Safety shoes
Safety gloves for protection against cuts
Safety helmet (when using lifting equipment)
Locally applicable laws and regulations on work safety and ac-
cident prevention must be complied with.
The procedure described in the installation and operating in-
structions for shutting down the product/unit must be strictly
observed.
Disconnect the device from the mains and secure it against be-
ing switched on again without authorisation.
All rotating parts must be at a standstill.
Close the gate valve in the inlet and in the pressure pipe.
Provide adequate aeration in enclosed spaces.