lnstrument Description
The Tektronix DC 5010 is a programmable universal
counterltimer plug-in. It features reciprocal frequency, Peri-
od, Ratio, and Events B During A measurements to
350 MHz. For timing measurements, the time interval,
width, risetime and falltime functions feature 3.1 25 nsec sin-
gle-shot resolution. For these measurements, averaging and
identical A and B channels provide increased accuracy. Also
included is a time manual mode, as well as three 350 MHz
totalize modes (A, A+ B, and A- B). The DC 501 0 also has
Standard Accessories
1 Instruction Manual
1 Reference Guide
1 Cable Assembly, bnc-to-slide on connector
NOTE
an auto-trigger feature, a probe-compensation feature, an
auto averages function, and an extensive set of automatic
Refer to the tabbed Accessories page at the rear of
power-up sell' tests.
this manual for more information.
The DC 51010 is an IEEE 488 (GPIB) Digital Interface
programmablle counter that allows any manually selectable
function or mode to be operated over the GPlB bus, includ-
performance Conditions
ing all input conditioning controls.
The limits stated in the Performance Requirements col-
umns of the following tables are valid only if the DC 5010
The IEEE standard identifies the interface functions of an
has been calibrated at an ambient temperature between
instrument or) the GPlB in terms of interface function sub-
+20oC and +300c and is operating at an ambient tern-
sets. The subsets are defined in the standard. The subsets
perature between
ooc
and + 5 0 0 ~ , unless otherwise
that apply to the DC 501 0 are listed in Table 1-5 at the end
of this section.
lnformation given in the Supplemental lnformation and
The DC 5010 has a DVM mode that reads
Out
the
Description columns of the following tables is provided for
nel A and channel B trigger level voltages. Shaped outputs
and an arming input are available at the front panel. Also
user information only and should not be interpreted as Per-
available at the front panel is a signal for use with the probe
formance Check requirements.
compensation function.
The DC 5010 must be operated or stored in an environ-
The operating modes and front-panel settings of the
ment whose limits are described under Environmental
DC 501 0 can be set and read by programming mnemonics
Characteristics.
set to it in ASCII code over the bus. The DC 5010 connects
to the bus when installed in a GPIB-compatible TM 5000-
Series power module.
Allow at least 30 minutes warm-up time for operation to
specified accuracy, 60 minutes after storage in a high-
humidity environment.
The DC 50110 can be equipped with an optional, oven-
controlled, 10 MHz crystal oscillator to obtain an even more
stable and precise internal time base.
Instrument Options
Safety Certification
Option 01 replaces the internal 10 MHz time base (clock)
This instrument is listed with Underwriters Laboratories
circuit with a self-contained proportional temperature con-
Inc. under UL Standard 1244 (Electrical and Electronic Mea-
trolled oven oscillator for increased accuracy and stability.
suring and Testing Equipment).