6.3.5

Adjustment of the temperature sensor in the wash tank

In case the value of the wash tank temperature in the Aquanta Control display and the
temperature indicator on the crate washer do not match, it is recommendable to adjust the
temperature sensor in the washing tank.
The measured value in the Aquanta Control display and the temperature indicator on the
crate washer may differ because the temperature is measured in different places.
NOTE
The thermistor should only be adjusted after a warm-up time of at least 2 minutes. If there
is no temperature indicator on the crate washer, the temperature in the washing tank can
be measured manually by means of a thermometer.
To adjust the temperature sensor, proceed as follows:
1. Activate the TANK menu.
Fig. 6.6
2. Correct the displayed temperature value with the upper-key or down-key to match the
indicator on the crate washer (max. ± 5° degrees from the displayed value).
Fig. 6.7
3. Press the NEXT key to confirm.
6.3.6

Adjustment of the temperature sensor for the final rinsing

In case the value of the rinsing temperature in the Aquanta Control display and the
temperature indicator on the crate washer do not match, it is recommendable to adjust the
temperature sensor for the rinsing temperature.
The temperature sensor may only be adjusted with the rinsing program activated.
NOTE
The rinsing temperature must be measured manually using a thermometer before starting
the adjustment.
To adjust the temperature sensor, proceed as follows:
1. Activate the RINSE AID menu.
Fig. 6.8
2. Correct the temperature value with the upper-key or down-key to match the indicator on
the crate washer (max. ± 5 degrees from the displayed value).
Fig. 6.9
3. Press the NEXT key to confirm.
417101386_AquantaControl_II.doc
55C = temperature in °C measured by the temperature sensor.
60C (5) = corrected temperature value with adjustment value
in brackets.
80C =
temperature in °C measured by the temperature sensor.
85C (5) = corrected temperature value with adjustment value
in brackets.