Visualization on a PC

As of Software Version ≥ V2.00 and in connection with "LabView" PC software (≥ V2.00) the
operating states and measured values can be visualized on a PC via the RS485 port on the
unit:
5.4

Functions for Manual Metering

The outputs for the detergent 1 metering unit, the detergent 2 metering unit, the rinse aid
metering unit, the additive metering unit and the external alarm (buzzer) can be activated
manually according to the respective configuration by the MANUAL DOSING FUNCTIONS
menu.
5.5

Functions for the Access Protection

The functions for the access protection can also be input and transmitted by the PC in
NOTE
connection with the "AquantaGet" PC software.
The access code can be activated, deactivated and changed with the ACCESS CODE
FUNCTIONS menu.
To activate the access code, proceed as follows:
1. Activate the ACCESS CODE FUNCTIONS menu with the ENTER-key.
2. Activate the ACTIVATE ACCESS CODE menu with the ENTER-key.
3. Enter the desired 4-digit code in the INPUT CODE menu.
4. Press NEXT to confirm the code.
To deactivate the access code, proceed as follows:
1. Activate the DEACTIVATE ACCESS CODE menu with the ENTER-key.
2. Enter the current code in the INPUT CODE menu.
3. Press NEXT to confirm deactivation of the code.
To change the code, proceed as follows:
1. Activate the CHANGE ACCESS CODE menu.
2. Press the ENTER-key and enter the previously valid code in the INPUT OLD CODE
menu.
3. Press NEXT and a new code in the INPUT NEW CODE menu.
4. Press NEXT to confirm the new code.