Display of the fault message report

An fault message report with up to 250 fault messages can be displayed with this menu. The
data in the fault message report include the date and time of the alarm recording as well as
the time between occurrence of the alarm and repair of the fault. The most recent error
message is displayed first.
NOTE
The following is displayed if no alarms are reported:
3. Activate DISPLAY FAULT MESSAGE LOG in the program.
4. Press the ENTER-key to display the first fault message.
Fig. 5.4
3. Press NEXT to display the time the fault occurs as well as the time between the
occurrence of the alarm and repair of the fault.
Fig. 5.5
4. Scroll with the NEXT key to show all the recorded fault messages.
NOTE
The display of the fault messages can be canceled prematurely by pressing the ENTER-key.
5.3

Data Transmission and Print Function

IMPORTANT
NOTE
5.3.1

Printing of consumption data, alarm report, configuration and parameters

The consumption data, the error message log and the configuration data with the
parameters can only be read and printed from the PC using Aquanta Control in conjunction
NOTE
with the PC software AquantaGet (≥ V2.00) via the RS485 connection on the unit. Only the
configuration data can be read when using Aquanta Basic. No other data transfers are
possible.
5.3.2
Reading out and deleting operating data with the PC, configuring and parameterizing
the unit
Only with Aquanta Control and in connection with the "AquantaGet" PC software
(≥ V2.00) the following communications can be made by the PC via the RS485 port on the
unit:
• Set date/time (the date and time is transmitted by the PC).
• Read out the configuration (with parameters) (is also possible with Aquanta Basic),
change on the PC and transmit again.
• Read out and delete the operating data.
• Read out and delete the alarm data.
• Activate, deactivate or change the access code.
417101386_AquantaControl_II.doc
01/
01.01.01: = date of the recorded alarm.
01/
12:00:
xxx min: = time between occurrence of alarm and repair of fault.
Data can be transmitted only with the Aquanta Control via the RS485 interface on the
instrument.
In connection with the AquantaGet PC software (Version ≥ V2.00) it is also possible to
read out the data with an activated access code, however, no changes can be made to the
configuration and parameter settings!
= fault message no. 1 (of max. 250 fault messages)
= fault message no. 1
= time of the recorded alarm.
- 63 -
Fig. 5.3
Rev. 4-2/10