Operating faults
12
Operating faults
12.1
Metering warning messages (display)
Display Meaning
reserve report
Operating faults: Metering warning messages (display): reserve report
Operating faults: Metering warning messages (display): empty report
metering lock (only
possible if this is
Operating faults: Metering warning messages (display): metering lock
Indicator in operation
mode 4..20 mA flashes
standard signal
monitoring responds
Operating faults: Metering warning messages (display): standard signal monitoring
standard signal is
--.-
Operating faults: Metering warning messages (display): standard signal is above 23.0 mA
417101442 Rev. 12-02.2019
Effect
pump continues
(flashing)
empty report
pump is stopped
pump is stopped
configured)
pump is stopped
pump runs in
above 23 mA
continuous operation
Cause
low-level advance
running
warning active
empty report active
no external enable of
the pump
standard signal is
under 3mA or cable to
standard signal
connection is broken
standard signal
exceeds the display
range
112
Remedy
Refill the metering
medium
Refill the metering
medium
Activate external
enable or deactivate
the metering lock in the
configuration menu.
Ä Chapter
(
10.3.7 'Configuration /
Metering lock'
on page 75)
check the standard
signal or cable
reduce the standard
signal