4.5
Side slip tester
Risk of slipping due to rough and moving sur-
faces and in wet conditions!
Safety measures:
Install an information sign (Risk of slipping!).
Keep the side slip tester free of contamination, snow
and moisture.
4.6
Pull-down device
Mechanical hazard from high pressure!
Exceeding the maximum pressure of the hyd-
raulic lifting device can lead to injury.
Safety measures:
Do not use the pull-down device with an extended
lifting device.
Do not drive the vehicle off the brake tester while
pulled down.
Only use the straps provided by the manufacturer.
The straps are subject to the inspection intervals of
the manufacturer.
4.7
Air pressure sensor cable
Mechanical hazard when screwing the air pres-
sure sensors onto the brake tester!
Driving onto the brake tester may cause the
motors to start automatically, depending on
the mode selected.
Safety measures:
Connect or remove the air pressure sensors only
outside the brake tester.
Do not move the vehicle while connecting the air
pressure sensors.
Use a pit guard to make sure the brake tester will not
be activated while the air pressure sensors are being
screwed on or removed in the working pit.
Robert Bosch GmbH
Safe handling | Brake Test Equipment | 33
Only qualified personnel may connect or remove the
air pressure sensors.
Connect the air pressure sensors only to the test
connections attached for that purpose (compressed-
air connection for 9 bar max.).
Risk of tripping due to improperly routed
lines!
Safety measures:
Route the lines properly.
4.8
Wireless air pressure sensors
Mechanical hazard when screwing the air pres-
sure sensors onto the brake tester!
Driving onto the brake tester may cause the
motors to start automatically, depending on
the mode selected.
Safety measures:
Connect or remove the air pressure sensors only
outside the brake tester.
Do not move the vehicle while connecting the air
pressure sensors.
Use a pit guard to make sure the brake tester will not
be activated while the air pressure sensors are being
screwed on or removed in the working pit.
Only qualified personnel may connect or remove the
air pressure sensors.
Connect the air pressure sensors only to the test
connections attached for that purpose (compressed-
air connection for 9 bar max.).