Herunterladen Diese Seite drucken

HP ProLiant Gen8 Handbuch Seite 456

Vorschau ausblenden Andere Handbücher für ProLiant Gen8:

Werbung

Verfügbare Sprachen

Verfügbare Sprachen

Storage Enclosure on SCSI
Bus X Indicated an
Overheated Condition... 17
Storage Enclosure on SCSI
Bus X Indicated a Power
Supply Failure... 16
Storage Enclosure on SCSI
Bus X Indicated that the Fan
Failed... 17
Storage Enclosure on SCSI
Bus X Indicated that the Fan
is Degraded... 17
Storage Enclosure on SCSI
Bus X Indicated that the Fan
Module is Unplugged... 17
Storage enclosure on SCSI Bus
X is unsupported with its
current firmware version...
17
Storage Enclosure on SCSI
Bus X - Wide SCSI Transfer
Failed... 17
Speicherfehler
1706-Smart Array Controller
Extended BIOS Data Area
Memory Corrupted. 63
201-Memory Error 46
203-Memory Address Error
46
Uncorrectable Memory Error
(Slot X, Memory Module
Y)... 95
Write Memory Error 22
Speichergrößenänderung des
Array-Beschleunigers erkannt
67
Speicherkarten
210-Memory Board Failure on
board X 49
210-Memory Board Power
Fault on board X 49
SSH, Fehlerbehebung 264
SSH, Textunterstützung von einer
Remote Console Sitzung 264
SSL, testen 270
SSO-Protokollmeldungen 207
Statusanzeigen, Controller 99
Stromversorgungsfehler 39
432 Index
Super-Kapazität, ersetzen
1705-Slot X Drive Array –
Please install Array
Accelerator Super-Cap... 63
1705-Slot X Drive Array -
Please replace Cache Module
Super-Cap... 63
SysLog-Meldungen, Onboard
Administrator 178
Systembatterie 58
Systemlüfter
System Fan Failure (Fan X,
Location) 94
System Fans Not Redundant
94
Systemlüfterausfall 94
Systemlüfter nicht redundant 94
Systemplatine
102-System Board Failure 44
102-System Board Failure,
CMOS Test Failed. 44
102-System Board Failure,
DMA Test Failed 44
102-System Board Failure,
Timer Test Failed 45
System Board is Unable to
Identify which Slots the
Controllers are in 19
Systemplatinenfehler
102-System Board Failure 44
102-System Board Failure,
CMOS Test Failed. 44
102-System Board Failure,
DMA Test Failed 44
102-System Board Failure,
Timer Test Failed 45
Systemstartprobleme 34
T
Tastatur
Network Server Mode Active
and No Keyboard Attached
38
No Keyboard Present 38
Tastatur, inkorrekte LED-
Anzeige 263
Temperatur
1610-Temperature Violation
Detected. - Waiting 5 Minutes
for System to Cool 58
High Temperature Condition
detected by Processor X 36
Temperature violation detected
- system Shutting Down in X
seconds 40
Testen von SSL 270
Timeout des EISA-
Erweiterungsbus-Masters 93
Trap-Kategorien 218
Trap-Meldungen 256
U
Überhitzung 94
Überhitzung des Systems 94
Unbekannte Modul-Ereignisse,
Virtual Connect 231
Unbekannter
Deaktivierungscode 21
Ungültiges Kennwort
Invalid Password - System
Halted! 37
Invalid Password - System
Restricted! 37
Unkorrigierbarer interner Fehler
des Prozessors 93
Unzulässiger Opcode 36
USB-Flash-Gerät 42
V
Verbindungsaufbau zu iLO nicht
möglich 255
Verbindungsaufbau zu iLO
Prozessor über NIC nicht
möglich 255
Verbindungsaufbau zur iLO IP-
Adresse nicht möglich 256
Verbindungskonflikt des
gemeinsam genutzten SAS-
Ports 78
Verbindungsmoduleinschubs-
Protokollmeldungen 180
Verbindung zwischen
Controllern 10
Verwaltungsport nicht nach Namen
zugänglich 254
Verwaltungs-
Protokollmeldungen 196
Verzeichnisdienste,
Fehlerbeseitigung 258
Verzeichnisfehler 254
DEWW

Werbung

loading