Herunterladen Diese Seite drucken

Meldungs-Ids 24750-24774 - HP ProLiant Gen8 Handbuch

Vorschau ausblenden Andere Handbücher für ProLiant Gen8:

Werbung

Verfügbare Sprachen

Verfügbare Sprachen

Meldungs-IDs 24750-24774

Meldungs-ID: 24750
Schweregrad: Warnung
Protokollmeldung: The external Smart Array controller located in the MSA
chassis labeled as <chassis label> has reported that a SAS link error has
been detected between port <port number> and the switch expander
connected to this port. Please check this data path and the associated
hardware.
The external Smart Array controller reporting this event is attached to
the host side Smart Array controller <controller name / slot information>.
Meldungs-ID: 24751
Schweregrad: Warnung
Protokollmeldung: The external Smart Array controller located in the MSA
chassis labeled as <chassis label> has reported that a SAS link error has
been detected between a switch expander and I/O module <module number> of
box <box number>. This hardware is connected to port <port number> of the
external array controller. Please check this data path and the associated
hardware.
The external Smart Array controller reporting this event is attached to
the host side Smart Array controller <controller name / slot information>.
Meldungs-ID: 24752
Schweregrad: Informativ
Protokollmeldung: The external Smart Array controller located in the MSA
chassis labeled as <chassis label> has reported that storage box number
<box number> was added to port <port number>. This connection is through
I/O module number <module number> on the storage box.
The external Smart Array controller reporting this event is attached to
the host side Smart Array controller <controller name / slot information>.
Meldungs-ID: 24753
Schweregrad: Fehler
Protokollmeldung: The external Smart Array controller located in the MSA
chassis labeled as <chassis label> has reported that storage box number
<box number> was removed from port <port number>. This connection was
through I/O module number <module number> on the storage box. This event
can occur when either a sole I/O module or data cable is removed.
The external Smart Array controller reporting this event is attached to
the host side Smart Array controller <controller name / slot information>.
Meldungs-ID: 24754
Schweregrad: Warnung
Protokollmeldung: The external Smart Array controller located in the MSA
chassis labeled as <chassis number> has reported that either redundant
I/O module number <module number> in box <box number> was removed or the
146 Kapitel 3 HP Smart Array-Fehler
DEWW