but the cache module flash memory is missing. This is an unsupported
configuration.
The external Smart Array controller is attached to the host side Smart
Array controller <controller name / slot information>.
Meldungs-ID 24807
Schweregrad: Warnung
Protokollmeldung: Array controller <controller name / slot information> has
reported that the cache module flash memory is installed but Supercap is
disabled. This is an unsupported configuration.
Meldungs-ID 24808
Schweregrad: Warnung
Protokollmeldung: The external Smart Array controller located in the MSA
chassis labeled as <chassis label> has reported that the cache module
flash memory is installed but Supercap is disabled. This is an
unsupported configuration.
The external Smart Array controller is attached to the host side Smart
Array controller <controller name / slot information>.

Smart Array Windows-Treiberfehler

Meldungs-ID: 5001
Schweregrad: Fehler
Protokollmeldung: The controller in slot %3 (bus %4, device %5, function %6)
heartbeat has not changed in %2 seconds.
Meldungs-ID: 5002
Schweregrad: Fehler
Protokollmeldung: The driver has taken the failed controller in slot %2
(bus %3, device %4, function %5) offline.
Meldungs-ID: 5003
Schweregrad: Fehler
Protokollmeldung: The controller (bus %2, device %3, function %4) has failed.
Invalid driver configuration buffer.
Meldungs-ID: 5004
Schweregrad: Fehler
Protokollmeldung: The controller (bus %2, device %3, function %4) has failed.
Critical memory allocation failure.
Meldungs-ID: 5005
Schweregrad: Fehler
Protokollmeldung: The controller (bus %2, device %3, function %4) failed to
post.