The external Smart Array controller is attached to the host side Smart
Array controller <controller name / slot information>.
Meldungs-ID: 24773
Schweregrad: Informativ
Protokollmeldung: The external Smart Array controller located in the MSA
chassis labeled as <chassis number> has reported that a tape drive has
been <inserted / removed>.
The external Smart Array controller is attached to the host side Smart
Array controller <controller name / slot information>.
Meldungs-ID: 24774
Schweregrad: Informativ
Protokollmeldung: The external Smart Array controller located in the MSA
chassis labeled as <chassis label> is reporting <link up / down> for PHY
number <PHY number>. This PHY link status change has occurred on port
<port number> of the external array controller.
The external Smart Array controller reporting this event is attached to
the host side Smart Array controller <controller name / slot information>.

Meldungs-IDs 24775-24799

Meldungs-ID: 24775
Schweregrad: Warnung
Protokollmeldung: The external Smart Array controller located in the MSA
chassis labeled as <chassis label> is reporting that the <drive type>
physical hard drive located in bay <bay number> is offline. The offline
reason received from the HP Smart Array firmware is: <firmware error
code>.
The external Smart Array controller is attached to the host side Smart
Array controller <controller name / slot information>.
<firmware error code>-Werte:
TOO_SMALL_IN_LOAD_CONFIG - Replacement drive is too small for
configured volume(s).
ERROR_ERASING_RIS - Could not write to reserved configuration sectors
after multiple retries.
ERROR_SAVING_RIS - Could not write to reserved configuration sectors
after multiple retries.
FAIL_DRIVE_COMMAND - "Fail Drive" command received from host.
MARK_BAD_FAILED - Unable to create media defect after multiple retries.
MARK_BAD_FAILED_IN_FINISH_REMAP - Unable to create media defect after
multiple retries.
TIMEOUT - Too many SCSI command timeouts.
AUTOSENSE_FAILED - Drive is failing commands but is not returning SCSI
sense data after multiple retries.