"INTERIM RECOVERY MODE"
"READY FOR RECOVERY"
"RECOVERING"
"WRONG PHYSICAL DRIVE REPLACED"
"PHYSICAL DRIVE NOT PROPERLY CONNECTED"
"HARDWARE IS OVERHEATING"
"HARDWARE HAS OVERHEATED"
"EXPANDING"
"NOT YET AVAILABLE"
"QUEUED FOR EXPANSION"
"DISABLED DUE TO SCSI ID CONFLICT"
"EJECTED"
"ERASING"
"UNKNOWN"
Meldungs-ID: 24713
Schweregrad: Informativ
Protokollmeldung: The external Smart Array controller located in the MSA
chassis labeled as <chassis label> has reported that logical drive
<logical drive number> is in a failed state but has had one or more drive
replacements and is now ready to change to a status of "OK". However,
this status change will not occur until the logical drive is re-enabled.
Please re-enable the logical drive either via the HP Array Configuration
Utility or by power cycling the MSA chassis.
The external Smart Array controller is attached to the host side Smart
Array controller <controller name / slot information>.
Meldungs-ID: 24714
Schweregrad: Warnung
Protokollmeldung: The external Smart Array controller located in the MSA
chassis labeled as <chassis label> has reported that the recovery of
logical drive <logical drive number> was aborted while rebuilding due to
an unrecoverable read error. Physical drive number <physical drive number
1> was the replacement drive being rebuilt before the read error
occurred, while physical drive number <physical drive number 2> is the
error drive which reported the read error.
The external Smart Array controller is attached to the host side Smart
Array controller <controller name / slot information>.
Meldungs-ID: 24715
Schweregrad: Warnung
138 Kapitel 3 HP Smart Array-Fehler