Herunterladen Diese Seite drucken

HP ProLiant Gen8 Handbuch Seite 168

Vorschau ausblenden Andere Handbücher für ProLiant Gen8:

Werbung

Verfügbare Sprachen

Verfügbare Sprachen

Protokollmeldung: The external Smart Array controllers located in the MSA
chassis labeled as <chassis label> are no longer redundant because both
array controllers cannot see all the physical drives.
The external Smart Array controller reporting this event is attached to
the host side Smart Array controller <controller name / slot information>.
Meldungs-ID: 24741
Schweregrad: Fehler
Protokollmeldung: The external Smart Array controllers located in the MSA
chassis labeled as <chassis label> are no longer redundant because one or
more drives has been determined not to be able to support redundant
controller operations.
The external Smart Array controller reporting this event is attached to
the host side Smart Array controller <controller name / slot information>.
Meldungs-ID: 24742
Schweregrad: Fehler
Protokollmeldung: The external Smart Array controllers located in the MSA
chassis labeled as <chassis label> are no longer redundant because an
expand operation is in progress. The controllers will become redundant
once again once the expand operation has completed.
The external Smart Array controller reporting this event is attached to
the host side Smart Array controller <controller name / slot information>.
Meldungs-ID: 24743
Schweregrad: Warnung
Protokollmeldung: The external Smart Array controller located in the MSA
chassis labeled as <chassis label> has reported that a SAS link error has
been detected between port <port number> of the external controller and I/
O module number <module number> of box number <box number>. Please check
this data path and the associated hardware.
The external Smart Array controller reporting this event is attached to
the host side Smart Array controller <controller name / slot information>.
Meldungs-ID: 24744
Schweregrad: Warnung
Protokollmeldung: The external Smart Array controller located in the MSA
chassis labeled as <chassis label> has reported that a SAS link error has
been detected between port <port number> and <attached device><attached
device index>. Please check this data path and the associated hardware.
The external Smart Array controller reporting this event is attached to
the host side Smart Array controller <controller name / slot information>.
Meldungs-ID: 24745
Schweregrad: Warnung
Protokollmeldung: The external Smart Array controller located in the MSA
chassis labeled as <chassis label> has reported that a SAS link error has
144 Kapitel 3 HP Smart Array-Fehler
DEWW

Werbung

loading