Protokollmeldung: A SAS link error has been detected in bay <bay number> of
box <box number> which is connected to port <port number> of array
controller <controller name / slot information>. Please check this data
path and the associated hardware.
Meldungs-ID: 24698
Schweregrad: Warnung
Protokollmeldung: A SAS link error has been detected between array controller
<controller name / slot information> and the switch expander connected to
port <port number> of this controller. Please check this data path and
the associated hardware.
Meldungs-ID: 24699
Schweregrad: Warnung
Protokollmeldung: A SAS link error has been detected between a switch expander
and I/O module <module number> of box <box number>. These boxes are
connected to port <port number> of array controller <controller name /
slot information>. Please check this data path and the associated
hardware.

Meldungs-IDs 24700-24724

Meldungs-ID: 24700
Schweregrad: Informativ
Protokollmeldung: The external Smart Array controller located in the MSA
chassis labeled as <chassis label> has reported that a <drive type>
physical hard drive in bay <bay number> was <inserted / removed>.
The external Smart Array controller is attached to the host side Smart
Array controller <controller name / slot information>.
Meldungs-ID: 24701
Schweregrad: Fehler
Protokollmeldung: The external Smart Array controller located in the MSA
chassis labeled as <chassis label> has reported that fan number <fan
number> has failed. The external Smart Array controller may attempt to
shut down power and/or spin down the installed disk drive(s).
The external Smart Array controller is attached to the host side Smart
Array controller <controller name / slot information>.
Meldungs-ID: 24702
Schweregrad: Informativ
Protokollmeldung: The external Smart Array controller located in the MSA
chassis labeled as <chassis label> has reported that fan number <fan
number> is reporting a degraded condition.
The external Smart Array controller is attached to the host side Smart
Array controller <controller name / slot information>.
Meldungs-ID: 24703
DEWW
Smart Array-Meldungen im Windows-Ereignisprotokoll 131

Werbung