The external Smart Array controller is attached to the host side Smart
Array controller <controller name / slot information>.

Meldungs-IDs 24725-24749

Meldungs-ID: 24725
Schweregrad: Informativ
Protokollmeldung: The external Smart Array controller located in the MSA
chassis labeled as <chassis label> has reported that the consistency
initialization pass has completed for logical drive <logical drive
number>.
The external Smart Array controller is attached to the host side Smart
Array controller <controller name / slot information>.
Meldungs-ID: 24726
Schweregrad: Warnung
Protokollmeldung: The external Smart Array controller located in the MSA
chassis labeled as <chassis label> has reported an uncorrectable read
error during surface analysis operations for logical drive <logical drive
number>. A media error was encountered that is not correctable due to
media errors on other physical drive(s) belonging to this logical volume.
The uncorrectable media defects are between logical block address <lba
number 1> and logical block address <lba number 2>. The host will be
unable to read some blocks between this address range until the blocks
are overwritten. Capacity expansion operations must be avoided while the
blocks are unreadable.
The external Smart Array controller is attached to the host side Smart
Array controller <controller name / slot information>.
Meldungs-ID: 24727
Schweregrad: Informativ
Protokollmeldung: The external Smart Array controller located in the MSA
chassis labeled as <chassis label> has reported that the surface analysis
uncorrectable read error condition for logical drive <logical drive
number> has ended. The previously reported media defects have been
overwritten. Capacity expansion operations may now be conducted.
The external Smart Array controller is attached to the host side Smart
Array controller <controller name / slot information>.
Meldungs-ID: 24728
Schweregrad: Informativ
Protokollmeldung: The external Smart Array controller located in the MSA
chassis labeled as <chassis label> has reported that a firmware update is
needed for the physical drive with product ID <ID number>. The
recommended minimum firmware revision should be <firmware revision
number>.
The external Smart Array controller is attached to the host side Smart
Array controller <controller name / slot information>.
DEWW
Smart Array-Meldungen im Windows-Ereignisprotokoll 141