between port <port number> and box <box number>. <firmware information>.
Please check the cabling and ensure that a supported configuration is
being used.
The external Smart Array controller reporting this event is attached to
the host side Smart Array controller <controller name / slot information>.
Meldungs-ID: 24760
Schweregrad: Warnung
Protokollmeldung: The external Smart Array controller located in the MSA
chassis labeled as <chassis label> has reported that an unsupported
configuration has occurred with the redundant cabling that is attached to
port <port number>. <firmware information>. Please check the cabling and
ensure that a supported configuration is being used.
The external Smart Array controller reporting this event is attached to
the host side Smart Array controller <controller name / slot information>.
Meldungs-ID: 24761
Schweregrad: Warnung
Protokollmeldung: The external Smart Array controller located in the MSA
chassis labeled as <chassis label> has reported that an unsupported
configuration has occurred with the redundant cabling that is attached to
port <port number>. Please check the cabling and ensure that a supported
configuration is being used.
The external Smart Array controller reporting this event is attached to
the host side Smart Array controller <controller name / slot information>.
Meldungs-ID: 24762
Schweregrad: Informativ
Protokollmeldung:
External Smart Array controller number <controller number> located in the
MSA chassis labeled as <chassis label> is reporting the following flash
operation: "<firmware message>."
The firmware was flashed from:
Revision: <old revision number>
to
Revision: <new revision number>
The external Smart Array controller is attached to the host side Smart
Array controller <controller name / slot information>.
Meldungs-ID: 24763
Schweregrad: Warnung
Protokollmeldung: The external Smart Array controller located in the MSA
chassis labeled as <chassis label> has reported an uncorrectable read
error during rebuild operations for logical drive <logical drive number>.
The uncorrectable media defects are between logical block address <lba
number 1> and logical block address <lba number 2>. The host will be
148 Kapitel 3 HP Smart Array-Fehler