Herunterladen Diese Seite drucken

HP ProLiant Gen8 Handbuch Seite 157

Vorschau ausblenden Andere Handbücher für ProLiant Gen8:

Werbung

Verfügbare Sprachen

Verfügbare Sprachen

Schweregrad: Informativ
Protokollmeldung: The external Smart Array controller located in the MSA
chassis labeled as <chassis label> has reported that redundant power
supply number <power supply number> is no longer sensed as being in a
failed state. Some possible reasons that would cause this state change to
occur include:
1. The previously failed power supply has returned to an operational
state.
2. The previously failed power supply was removed from the chassis.
The external Smart Array controller is attached to the host side Smart
Array controller <controller name / slot information>.
Meldungs-ID: 24709
Schweregrad: Fehler
Protokollmeldung: The external Smart Array controller located in the MSA
chassis labeled as <chassis label> is reporting a drive failure
notification for the <drive type> physical hard drive located in bay <bay
number>. The failure reason received from the HP Smart Array firmware is:
<firmware error code>.
The external Smart Array controller is attached to the host side Smart
Array controller <controller name / slot information>.
<firmware error code>-Werte:
TOO_SMALL_IN_LOAD_CONFIG - Replacement drive is too small for
configured volume(s).
ERROR_ERASING_RIS - Could not write to reserved configuration sectors
after multiple retries.
ERROR_SAVING_RIS - Could not write to reserved configuration sectors
after multiple retries.
FAIL_DRIVE_COMMAND - "Fail Drive" command received from host.
MARK_BAD_FAILED - Unable to create media defect after multiple retries.
MARK_BAD_FAILED_IN_FINISH_REMAP - Unable to create media defect after
multiple retries.
TIMEOUT - Too many SCSI command timeouts.
AUTOSENSE_FAILED - Drive is failing commands but is not returning SCSI
sense data after multiple retries.
MEDIUM_ERROR_1 - Caused by a particular set of SCSI sense codes that
indicate the drive is in bad shape and its data may be corrupt.
MEDIUM_ERROR_2 - Caused by a particular set of SCSI sense codes that
indicate the drive is in bad shape; retries did not help.
NOT_READY_BAD_SENSE - Drive is returning unrecognized Not Ready sense
codes.
NOT_READY - Drive is not ready and will not spin up.
DEWW
Smart Array-Meldungen im Windows-Ereignisprotokoll 133

Werbung

loading