Protokollmeldung: The consistency initialization pass has completed for
logical drive <logical drive number> of array controller <controller
name / slot information>.
Meldungs-ID: 24685
Schweregrad: Warnung
Protokollmeldung: Array controller <controller name / slot information> has
reported an uncorrectable read error during surface analysis operations
for logical drive <logical drive number>. A media error was encountered
that is not correctable due to media errors on other physical drive(s)
belonging to this logical volume. The uncorrectable media defects are
between logical block address <block address 1> and logical block address
<block address 2>. The host will be unable to read some blocks between
this address range until the blocks are overwritten. Capacity expansion
operations must be avoided while the blocks are unreadable.
Meldungs-ID: 24686
Schweregrad: Informativ
Protokollmeldung: Array controller <controller name / slot information> has
reported that the surface analysis uncorrectable read error condition for
logical drive <logical drive number> has ended. The previously reported
media defects have been overwritten. Capacity expansion operations may
now be conducted.
Meldungs-ID: 24687
Schweregrad: Informativ
Protokollmeldung: A firmware update is needed for the physical drive with
product ID <ID number> connected to array controller <controller name /
slot information>. The recommended minimum firmware revision should be
<revision number>.
Meldungs-ID: 24688
Schweregrad: Informativ
Protokollmeldung: Power supply number <power supply number> was <inserted /
removed>. This power supply is located in box <box number> which is
attached to port <port number> of array controller <controller name /
slot information>.
Meldungs-ID: 24690
Schweregrad: Warnung
Protokollmeldung: A SAS link PHY error has been detected. The PHY error
threshold has been exceeded for PHY number <PHY number> located on
expander number <expander number>. This expander can be found in box <box
number> which is attached to port <port number> of array controller
<controller name / slot information>.
Meldungs-ID: 24691
Schweregrad: Warnung
Protokollmeldung: A SAS link error has been detected between port <port
number> of array controller <controller name / slot information> and I/O
DEWW