Herunterladen Diese Seite drucken

HP ProLiant Gen8 Handbuch Seite 173

Vorschau ausblenden Andere Handbücher für ProLiant Gen8:

Werbung

Verfügbare Sprachen

Verfügbare Sprachen

unable to read some blocks between this address range until the blocks
are overwritten. The logical drive rebuild is continuing so that the
volume can regain fault tolerance. Capacity expansion operations must be
avoided while the affected blocks are unreadable.
The external Smart Array controller is attached to the host side Smart
Array controller <controller name / slot information>.
Meldungs-ID: 24764
Schweregrad: Warnung
Log message:The external Smart Array controller located in the MSA chassis
labeled as <chassis label> is reporting that the <drive type> physical
hard drive located in bay <bay number> is not supported <not supported
reason>.
The external Smart Array controller is attached to the host side Smart
Array controller <controller name / slot information>.
<not supported reason>-Werte:
"because it is a singled ported drive"
"because it is a SATA drive"
"because it is smaller than the drive it is replacing"
"because it is of an unrecognized type"
"because it contains an unsupported RIS configuration"
Meldungs-ID: 24765
Schweregrad: Informativ
Protokollmeldung: The MSA chassis labeled as <chassis label> has reported that
battery pack number <battery pack number> located on controller number
<controller number> has been <inserted / removed>.
The external Smart Array controller reporting this operation is attached
to the host side Smart Array controller <controller name / slot
information>.
Meldungs-ID: 24766
Schweregrad: Warnung
Protokollmeldung: The external Smart Array controller located in the MSA
chassis labeled as <chassis label> is reporting that the <drive type>
physical hard drive located in bay <bay number> is in a SMART predictive
failure state.
The external Smart Array controller is attached to the host side Smart
Array controller <controller name / slot information>.
Meldungs-ID: 24767
Schweregrad: Informativ
Protokollmeldung: The external Smart Array controller located in the MSA
chassis labeled as <chassis label> has reported that more physical
DEWW
Smart Array-Meldungen im Windows-Ereignisprotokoll 149

Werbung

loading