Schweregrad: Warnung
Protokollmeldung: Redundant path number <path number> for the <drive type>
physical drive located in bay <bay number> has either failed or been
removed. The drive can be found in box <box number> which is attached to
port <port number> of array controller <controller name / slot
information>.
Meldungs-ID: 24595
Schweregrad: Fehler
Protokollmeldung: A drive failure notification has been received for the
<drive type> physical drive located in bay <bay number>. This drive can
be found in box <box number> which is connected to port <port number> of
the array controller <controller name / slot information>. The failure
reason received from the HP Smart Array firmware is: <firmware error
code>.
<firmware error code>-Werte:
TOO_SMALL_IN_LOAD_CONFIG - Replacement drive is too small for
configured volume(s).
ERROR_ERASING_RIS - Could not write to reserved configuration sectors
after multiple retries.
ERROR_SAVING_RIS - Could not write to reserved configuration sectors
after multiple retries.
FAIL_DRIVE_COMMAND - "Fail Drive" command received from host.
MARK_BAD_FAILED - Unable to create media defect after multiple retries.
MARK_BAD_FAILED_IN_FINISH_REMAP - Unable to create media defect after
multiple retries.
TIMEOUT - Too many SCSI command timeouts.
AUTOSENSE_FAILED - Drive is failing commands but is not returning SCSI
sense data after multiple retries.
MEDIUM_ERROR_1 - Caused by a particular set of SCSI sense codes that
indicate the drive is in bad shape and its data may be corrupt.
MEDIUM_ERROR_2 - Caused by a particular set of SCSI sense codes that
indicate the drive is in bad shape; retries did not help.
NOT_READY_BAD_SENSE - Drive is returning unrecognized Not Ready sense
codes.
NOT_READY - Drive is not ready and will not spin up.
HARDWARE_ERROR - Drive is returning a Hardware Error sense key;
controller unable to get drive back online.
ABORTED_COMMAND - Drive is returning an Aborted Command sense key;
controller unable to get drive back online.
WRITE_PROTECTED - Drive is returning a sense key indicating it is
write protected.