EN 78
3. Check if your compressor is switched on and set
correctly.
4. Open all required valves of your compressed air
supply system.
Does the air pressure fluctuate significantly so
that jobs are frequently interrupted?
If applicable:
1. Verify that your compressor can permanently gen-
erate the required air pressure and volume flow.
Not every compressor is designed for
commercial use with dental machines.
2. If necessary, replace your compressor with one that
meets the recommendations.
Installing the pneumatics – on page  20
The computer interrupts the job and displays
that the vacuum is too low
You can resolve this problem while the job
execution is interrupted. DENTALCNC
continues the job as soon as the problem is
resolved.
Is the suction unit switched on and operating?
How to check this:
1. Check if the suction hose is properly seated in the
corresponding opening and is undamaged.
2. If the machine controls the suction unit:
a. Check if the switching unit or data cable is
properly installed.
b. Try operating the suction unit without the
switching unit or data cable.
3. Switch on the suction unit.
4. Set the extraction level higher until the machine
continues the job.
Is the filter or container of the suction unit full?
If applicable:
Insert an empty filter into the suction unit or empty
the container.
Does the suction unit have an automatic
tapping function?
If applicable:
Choose a shorter tapping interval.
I have exchanged the tool magazine inserts
and now there are no holes for the tools
anymore
Tool magazine inserts are delivered without drilled
holes for tools. You drill them with the machine.
Original Operating Instructions:  R5
Version: 12/16/2021
Use DENTALCNC to drill new holes into the new
inserts.
R5 – Troubleshooting