Installing The Pneumatics; Overview Compressed Air Regulator - VHF R5 Originalbetriebsanleitung

Inhaltsverzeichnis

Werbung

Verfügbare Sprachen
  • DE

Verfügbare Sprachen

  • DEUTSCH, seite 85
EN 20

5.4 Installing the pneumatics

Risk of injuries through
WARNING
leaking compressed air and
lashing pneumatic hoses
Open or loose pneumatic connections can cause
severe injuries.
Ensure that during installation and maintenance
of the pneumatic hoses and of the compressed air
regulator compressed air is not conducted through
the hoses and connections.
Before conducting compressed air through the
hoses and connectors, verify that the hoses are
securely inserted into the correct connectors and
that they are not damaged. This also applies to the
compressed air regulator.
Do not conduct compressed air through damaged
hoses and connectors.
The spindle may suffer
NOTICE
bearing damage and electrical
damage if the compressed air is contaminated
The incoming compressed air must be dry and oil-free
according to ISO 8573-1:2010 because the
compressed air regulator only serves as an indicator
for contaminated air.
Air purity according to ISO 8573-1:2010
Solid
class 3
Filtration degree better than 5 µm
particles
for solid particles
Water
class 4
Maximum pressure dew point
content
+3 °C
Residual oil
class 3
Maximum oil content: 1 mg/m
content
Ensure that the compressed air meets the above
requirements.
Only connect the machine to the compressed air
supply if the compressed air regulator is properly
installed.
The machine requires the compressed air for the
following tasks:
For the opening and closing of the collet chuck
n
during tool changes.
For the spindle sealing air which prevents foreign
n
bodies from entering the spindle.
For the sealing air in the working chamber that
n
keeps machining debris away from sensitive
machine parts.
For the ionizer.
n

5.4.1 Overview compressed air regulator

The machine is connected to the external air supply via
a compressed air regulator. You can use this regulator
to monitor and regulate the pressure of the incoming
air.
The compressed air regulator is pre-installed in the
multi-purpose compartment. Location:
below
The regulator has the following connections:
You need to remove the tank before you can access
the compressed air regulator (
liquid and cleaning the tank – on page  33
F
IG
3
Original Operating Instructions:  R5
Version: 12/16/2021
R5 – Installing the machine
1/8" internal thread, fitted with male compressed
n
air connector to connect the external compressed
air supply
6 mm push-in fitting to connect the machine.
n
. 11 T
HE LOCATION OF THE COMPRESSED AIR REGULATOR
Fig. 11 see
Exchanging the cooling
).

Werbung