Herunterladen Inhalt Inhalt Diese Seite drucken

Endress+Hauser iTEMP TMT 165 FOUNDATION Fieldbus Betriebsanleitung Seite 117

Temperature transmitter
Inhaltsverzeichnis

Werbung

Verfügbare Sprachen

Verfügbare Sprachen

FOUNDATION Fieldbus temperature transmitter
Index
Parameter
29
SET_FSTATE
26
SHED_RCAS
27
SHED_ROUT
3
STRATEGY
1
ST_REV
2
TAG_DESC
8
TEST_RW
35
UPDATE_EVT
40
WRITE_ALM
34
WRITE_LOCK
Endress+Hauser
Resource Block
Write access with
operating mode
(MODE_BLK)
Dynamic
This paramter can be used to manually enable the security behaviour of the
device.
Static
Specifies the monitoring time for checking the connection between the
fieldbus host system and the PID function block in operating mode RCAS.
On expiry of the monitoring time the PID function block switches from
operating mode RCAS to the operating mode selected in the parameter
SHED_OPT
Factory default:
Static
Specifies the monitoring time for checking the connection between the
fieldbus host system and the PID function block in operating mode ROUT.
On expiry of the monitoring time the PID function block switches from
operating mode ROUT to the operating mode selected in the parameter
SHED_OPT (see page 154).
Factory default:
Static
Parameter for grouping for faster evaluation of blocks.
Grouping is carried out by entering the same numerical value in the
parameter STRATEGY for each individual block
Factory default:
2
This data is neither checked nor processed by the Resource Block.
Static/read only
Displays the revision status of the static data.
2
The revision status is incremented on each modification of static data.
Static
Entry of a user specific text for unique identification and assignment of the
block.
2
Dynamic
This parameter is required only for inter-operability tests and has no meaning
in normal operation.
Dynamic
Displays whether static block data has been modified, including date and
time.
AUTO - OOS
Displays the status of the write protected alarm.
2
• The alarm is triggered if the write protection is disabled.
Static
Able and disable write protection
Display:
Description
1
640000
/
ms
32
1
640000
/
ms
32
0
Note!
Note!
Note!
Note!
LOCKED
Device data cannot be modified
NOT LOCKED Device data can be modified
UNINITIALIZED
11 Appendix
117

Werbung

Kapitel

Inhaltsverzeichnis

Fehlerbehebung

loading

Inhaltsverzeichnis