11 Appendix
Index
Parameter
36
BLOCK_ALM
6
BLOCK_ERR
30
CLR_FSTATE
33
CONFIRM_
TIME
20
CYCLE_SEL
19
CYCLE_TYPE
9
DD_
RESOURCE
13
DD_REV
12
DEV_REV
11
DEV_TYPE
28
FAULT_STATE
114
Resource Block
Write access with
operating mode
(MODE_BLK)
Dynamic
Displays the current block status with information on pending configuration,
hardware or system errors, including details of the alarm time (date, time)
when the error occurred.
The block alarm is triggered in the event of the following block errors:
• SIMULATE ACTIVE
• OUT OF SERVICE
2
If the option of the alarm has not been enabled in the parameter
ACK_OPTION, the alarm can only be acknowledged via this parameter.
Dynamic/read only
Displays the active block error.
Display:
Dynamic
This parameter can be used to manually disable the security behaviour of the
Analogue Output and Discrete Output function blocks.
Static
Specifies the confirmation time for the event report. If the device does not
receive confirmation within this time then the event report is sent to the
fieldbus host system again.
Factory default:
Static
Displays the block exicution method used by the fieldbus host system.
2
The block execution method is selected by the fieldbus host system.
Static/read only
Dispalys the block exicution method supported by the device.
Display:
Static/read only
Displays the reference source for the device description in the device.
Display:
Static/read only
Displays the revision number of the device description.
Static/read only
Displays the revision number of the device
Static/read only
Displays the device type in decimal numeric format.
Display:
Dynamic
Current status display of the security behaviour of the Analogue Output and
Discrete Output function blocks.
FOUNDATION Fieldbus temperature transmitter
Description
Note!
SIMULATE ACTIVE
Simulation is possible in the Analogue Input function
block via the parameter SIMULATE (refer also to
Hardware Write Protection Configuration on page 97).
OUT OF SERVICE
The block has the status "Out Of Service".
1
640000
/
ms
32
Note!
SCHEDULED
timed block execution method
BLOCK EXECUTION
sequential block execution method
MANUF SPECIFIC
manufacturer specified
(NULL)
0 x 1200 hex for ProdType
Endress+Hauser