Connecting the System
Connection of the AC cables
• Plug the respective AC connector into the correspond-
ing jack for the AC connection by hand (ON-GRID,
BACK UP) until a "click" is heard or felt (7.1 / 7.2).
• Observe the following recommendations
regarding the parameters of the circuit breaker:
BACKUP:
ON-GRID:
  N oteonconnectingairconditioners
and similar appliances:
Some appliances, such as air conditioners,
require at least 2-3 minutes to restart
(balancing the refrigerant gas in the circuit)
and can be damaged if the power supply is
interrupted and restored after a short time.
Therefore, when connecting appliances
of this type, make sure they are equipped
with a time delay function.
Otherwise, the power output of the system
will be interrupted and an overload error will
be displayed; however, internal damage to cor-
responding appliances cannot be completely
ruled out in this case.
116
25 A / 400 VAC 6KA
32 A / 400 VAC 6KA